مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

996
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ULTRASOUND AS A SECONDARY CONFIRMATION METHOD AFTER ENDOTRACHEAL INTUBATION

Pages

  236-242

Abstract

 Introduction: Beside assessment by physical examination a device also should be used to confirm the correct position of ENDOTRACHEAL TUBE immediately after intubation. Recent studies have shown that ULTRASOUND can be a used to detect diaphragmatic motion as an indirect sign of endotracheal intubation.Our objective was to assess the sensitivity and specificity of ULTRASOUND for verification of tube position after intubation and to evaluate whether ULTRASOUND could be used as a usefull method for secondary confirmation of tube position.Materials and Methods: ULTRASOUND imaging was performed immediately after intubation for each patient. Scanning window was in right lower chest where the right lateral part of diaphragm could be imaged just on top of the liver. Then a second laryngoscopy was performed by the means of a glydoscope and tube position was assessed under direct visualization. Sensitivity, specificity and agreement between 2 methods were calculated.Results: Overall 100 patients with a mean age of 67.1±16.6 [SD] years were included in the study. The sensitivity and specificity of ULTRASOUND for correct tracheal intubation was 97% and 100% respectively. Agreement between ULTRASOUND and glydoscope in assessment of tube position was 0.713 which indicated that there was an acceptable agreement between the 2 methods. We successfully identified all 4 esophageal intubations and 9 tracheal intubations which had been positioned down in to the right main bronchus.Conclusion: Diaphragmatic ULTRASOUND is a rapid, noninvasive and useful method for assessment of ENDOTRACHEAL TUBE position.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    AHMADI, KOUROSH, PISHBIN, ELHAM, RAMEZANI, MAHSAN, & EBRAHIMI, MOHSEN. (2013). ULTRASOUND AS A SECONDARY CONFIRMATION METHOD AFTER ENDOTRACHEAL INTUBATION. MEDICAL JOURNAL OF MASHHAD UNIVERSITY OF MEDICAL SCIENCES, 56(4), 236-242. SID. https://sid.ir/paper/52029/en

    Vancouver: Copy

    AHMADI KOUROSH, PISHBIN ELHAM, RAMEZANI MAHSAN, EBRAHIMI MOHSEN. ULTRASOUND AS A SECONDARY CONFIRMATION METHOD AFTER ENDOTRACHEAL INTUBATION. MEDICAL JOURNAL OF MASHHAD UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2013;56(4):236-242. Available from: https://sid.ir/paper/52029/en

    IEEE: Copy

    KOUROSH AHMADI, ELHAM PISHBIN, MAHSAN RAMEZANI, and MOHSEN EBRAHIMI, “ULTRASOUND AS A SECONDARY CONFIRMATION METHOD AFTER ENDOTRACHEAL INTUBATION,” MEDICAL JOURNAL OF MASHHAD UNIVERSITY OF MEDICAL SCIENCES, vol. 56, no. 4, pp. 236–242, 2013, [Online]. Available: https://sid.ir/paper/52029/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button