مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

565
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

285
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECTIVE POINT OF MEASUREMENT IN CYLINDRICAL ION CHAMBER FOR MEGAVOLTAGE PHOTON BEAMS

Author(s)

SEIF FATEMEH | KARBALAYI MOJTABA | BAYATIANI MOHAMAD REZA | KARBALAYI MITRA | TAHMASEBI BIRGANI MOHAMAD JAVAD | Issue Writer Certificate 

Pages

  147-155

Abstract

 IntroductionFor dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an EFFECTIVE POINT OF MEASUREMENT (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and to evaluate the fixed EPOM that was recommended by standard DOSIMETRY PROTOCOLS.Materials and MethodsPercent depth doses (PDDs) for 6 MV and 18 MV were measured with two types of chambers for different depths and field sizes. The EPOM was calculated using results obtained from measurement data for two types of chambers, comparison of the readings, and using dosimetry, mathematical, and statistical consideration. For displacement correction factor Dr=0, Dr=0.6r and different Dr, the minimum standard deviations ratio (SDRs) were calculated at several depths and field sizes.ResultsMaximum level of SDRs was about 0.38% and 0.49% (when assuming variable Dr) for 6 MV and 18 MV, respectively (which was less than 0.5% and acceptable). This quantity was greater than one (for assuming = 0.6r) and greater than 2 when there was no shift (Dr =0)ConclusionThe results show that the recommended shift for cylindrical ion chamber in DOSIMETRY PROTOCOLS (upstream of 0.6r) is not correct and using a fixed value for the EPOM at all photon beam energies, depths, and field sizes is not suitable for accurate dosimetry.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SEIF, FATEMEH, KARBALAYI, MOJTABA, BAYATIANI, MOHAMAD REZA, KARBALAYI, MITRA, & TAHMASEBI BIRGANI, MOHAMAD JAVAD. (2013). EFFECTIVE POINT OF MEASUREMENT IN CYLINDRICAL ION CHAMBER FOR MEGAVOLTAGE PHOTON BEAMS. IRANIAN JOURNAL OF MEDICAL PHYSICS, 10(3), 147-155. SID. https://sid.ir/paper/628900/en

    Vancouver: Copy

    SEIF FATEMEH, KARBALAYI MOJTABA, BAYATIANI MOHAMAD REZA, KARBALAYI MITRA, TAHMASEBI BIRGANI MOHAMAD JAVAD. EFFECTIVE POINT OF MEASUREMENT IN CYLINDRICAL ION CHAMBER FOR MEGAVOLTAGE PHOTON BEAMS. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2013;10(3):147-155. Available from: https://sid.ir/paper/628900/en

    IEEE: Copy

    FATEMEH SEIF, MOJTABA KARBALAYI, MOHAMAD REZA BAYATIANI, MITRA KARBALAYI, and MOHAMAD JAVAD TAHMASEBI BIRGANI, “EFFECTIVE POINT OF MEASUREMENT IN CYLINDRICAL ION CHAMBER FOR MEGAVOLTAGE PHOTON BEAMS,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 10, no. 3, pp. 147–155, 2013, [Online]. Available: https://sid.ir/paper/628900/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button