مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

367
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

117
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CALCULATIONS OF LINAC PHOTON DOSE DISTRIBUTIONS IN HOMOGENEOUS PHANTOM USING SPLINE

Pages

  133-138

Abstract

 IntroductionRelative dose computation is a necessary step in radiation treatment planning. Therefore, finding an approach that is both fast and accurate seems to be necessary. The purpose of this work was to investigate the feasibility of natural CUBIC SPLINE to reconstruct dose maps for linear accelerator radiation treatment fields in comparison with those of the simulation.Materials and MethodsA natural CUBIC SPLINE algorithm was used to reproduce DOSE CALCULATIONs of linac radiation treatment fields resulting from GEANT4 application for tomographic emission (GATE) simulation. The spline algorithm was used to compute percent depth dose of radiation therapy fields for 6 MV X-rays, which were calculated by simulation of Elekta Compact Linac. It reconstructed 2-dimensional dose maps and created isodose distributions. This dose maps were evaluated and compared with the simulation, where the g -index was used.ResultsA good agreement was found between the doses calculated from the simulation and the spline. In particular, an average g-index passing rate of 0.24 was obtained for sample percent depth dose distributions, and an average g -index passing rate of 0.20 was observed for sample dose profiles.ConclusionNatural CUBIC SPLINE has been established to calculate dose maps from field characteristics. The feasibility and possibility of natural CUBIC SPLINE to calculate dose maps for linac radiation therapy fields in a homogeneous phantom has been demonstrated.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SADOUGHI, HAMID REZA, NASSERI, SHAHROKH, MOMENNEZHAD, MAHDI, SADOGHI YAZDI, HADI, ZAREI, MOHAMMAD HOSSEIN, & BAHREYNI TOOSI, MOHAMMAD HOSSEIN. (2013). CALCULATIONS OF LINAC PHOTON DOSE DISTRIBUTIONS IN HOMOGENEOUS PHANTOM USING SPLINE. IRANIAN JOURNAL OF MEDICAL PHYSICS, 10(3), 133-138. SID. https://sid.ir/paper/631735/en

    Vancouver: Copy

    SADOUGHI HAMID REZA, NASSERI SHAHROKH, MOMENNEZHAD MAHDI, SADOGHI YAZDI HADI, ZAREI MOHAMMAD HOSSEIN, BAHREYNI TOOSI MOHAMMAD HOSSEIN. CALCULATIONS OF LINAC PHOTON DOSE DISTRIBUTIONS IN HOMOGENEOUS PHANTOM USING SPLINE. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2013;10(3):133-138. Available from: https://sid.ir/paper/631735/en

    IEEE: Copy

    HAMID REZA SADOUGHI, SHAHROKH NASSERI, MAHDI MOMENNEZHAD, HADI SADOGHI YAZDI, MOHAMMAD HOSSEIN ZAREI, and MOHAMMAD HOSSEIN BAHREYNI TOOSI, “CALCULATIONS OF LINAC PHOTON DOSE DISTRIBUTIONS IN HOMOGENEOUS PHANTOM USING SPLINE,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 10, no. 3, pp. 133–138, 2013, [Online]. Available: https://sid.ir/paper/631735/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button