مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

98
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

56
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Stress Distribution in Implant-Supported Overdenture and Peri-Implant Bone Using Three Attachment Systems: A Finite Element Analysis

Pages

  57-61

Abstract

 Background: This Finite element analysis (FEA) evaluated stress distribution in implant-supported Overdenture (ISO) and peri-implant bone using one extracoronal (ball) and two intracoronal (locator and Zest Anchor Advanced Generation (ZAAG)) Attachment systems. Methods: In this in vitro study, the mandible was modelled in the form of an arc-shaped bone block with 33 mm height and 8 mm width. Two titanium implants were modelled at the site of canine teeth, and three Attachments (ZAGG, locator, and ball) were placed over them. Next, 100 N load was applied at 90° and 30° angles from the molar site of each quadrant to the implants. The stress distribution pattern in the implants and the surrounding bone was analyzed, and the von Mises stress around the implants and in the crestal bone was calculated. Results: While minimum stress in peri-implant bone following load application at 30° angle was noted in the mesial point of the locator Attachment, maximum stress was recorded at the distal point of the ball Attachment following load application at 90° angle. Maximum stress around the implant following load application at 90° angle was noted in the lingual point of the ball Attachment while minimum stress was recorded in the lingual point of the locator Attachment following load application at 90° angle. Conclusions: According to the results, the locator Attachment is preferred to the ZAAG Attachment, and the ball Attachment should be avoided if possible.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    IZADI, ALIREZA, Vafaie, Fariboorz, Shahbazi, Armaghan, & Mokri Vala, Mohamad Taghi. (2021). Stress Distribution in Implant-Supported Overdenture and Peri-Implant Bone Using Three Attachment Systems: A Finite Element Analysis. AVICENNA JOURNAL OF DENTAL RESEARCH, 13(2), 57-61. SID. https://sid.ir/paper/687594/en

    Vancouver: Copy

    IZADI ALIREZA, Vafaie Fariboorz, Shahbazi Armaghan, Mokri Vala Mohamad Taghi. Stress Distribution in Implant-Supported Overdenture and Peri-Implant Bone Using Three Attachment Systems: A Finite Element Analysis. AVICENNA JOURNAL OF DENTAL RESEARCH[Internet]. 2021;13(2):57-61. Available from: https://sid.ir/paper/687594/en

    IEEE: Copy

    ALIREZA IZADI, Fariboorz Vafaie, Armaghan Shahbazi, and Mohamad Taghi Mokri Vala, “Stress Distribution in Implant-Supported Overdenture and Peri-Implant Bone Using Three Attachment Systems: A Finite Element Analysis,” AVICENNA JOURNAL OF DENTAL RESEARCH, vol. 13, no. 2, pp. 57–61, 2021, [Online]. Available: https://sid.ir/paper/687594/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button