مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

241
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

103
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A COMPARISON OF THE DOSIMETRIC PARAMETERS OF CS-137 BRACHYTHERAPY SOURCE IN DIFFERENT TISSUES WITH WATER USING MONTE CARLO SIMULATION

Pages

  65-74

Abstract

 Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in BRACHYTHERAPY treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the water phantom is different from that of different tissues. The purpose of this study is to investigate the effects of the phantom materials on the TG-43 dosimetery parameters of the Cs-137 BRACHYTHERAPY source using MCNP4C MONTE CARLO code.Materials and Methods In this research, the Cs-137 (Model Selectron) BRACHYTHERAPY source was simulated in different phantoms (bone, soft tissue, muscle, fat, and the inhomogeneous phantoms of water/bone) of volume 27000 cm3 using MCNP4C MONTE CARLO code. *F8 tally was used to obtain the dose in a fine cubical lattice. Then the TG-43 dosimetry parameters of the BRACHYTHERAPY source were obtained in water phantom and compared with those of different phantoms.Results The percentage difference between the radial dose function g (r) of bone and the g (r) of water phantom, at a distance of 10 cm from the source center is 20%, while such differences are 1.7%, 1.6% and 1.1% for soft tissue, muscle, and fat, respectively. The largest difference of the dose rate constant of phantoms with those of water is 4.52% for the bone phantom, while the differences for soft tissue, muscle, and fat are 1.18%, 1.27%, and 0.18%, respectively. The 2D anisotropy function of the Cs-137 source for different tissues is identical to that of water.Conclusion The results of the simulations have shown that dose calculation in water phantom would introduce errors in the dose calculation around BRACHYTHERAPY sources. Therefore, it is suggested that the correction factors of different tissues be applied after dose calculation in water phantoms, in order to decrease the errors of BRACHYTHERAPY treatment planning.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SINA, SEDIGHEH, FAGHIHI, REZA, & SOLEIMANI MEIGOONI, ALI. (2012). A COMPARISON OF THE DOSIMETRIC PARAMETERS OF CS-137 BRACHYTHERAPY SOURCE IN DIFFERENT TISSUES WITH WATER USING MONTE CARLO SIMULATION. IRANIAN JOURNAL OF MEDICAL PHYSICS, 8(1), 65-74. SID. https://sid.ir/paper/694200/en

    Vancouver: Copy

    SINA SEDIGHEH, FAGHIHI REZA, SOLEIMANI MEIGOONI ALI. A COMPARISON OF THE DOSIMETRIC PARAMETERS OF CS-137 BRACHYTHERAPY SOURCE IN DIFFERENT TISSUES WITH WATER USING MONTE CARLO SIMULATION. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2012;8(1):65-74. Available from: https://sid.ir/paper/694200/en

    IEEE: Copy

    SEDIGHEH SINA, REZA FAGHIHI, and ALI SOLEIMANI MEIGOONI, “A COMPARISON OF THE DOSIMETRIC PARAMETERS OF CS-137 BRACHYTHERAPY SOURCE IN DIFFERENT TISSUES WITH WATER USING MONTE CARLO SIMULATION,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 8, no. 1, pp. 65–74, 2012, [Online]. Available: https://sid.ir/paper/694200/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button