مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

95
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

54
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Determination of Diagnostic Reference Level (DRL) in Common Computed Tomography Examinations with the Modified Quality Control-Based Dose Survey Method in Four University Centers: A Comparison of Methods

Pages

  447-458

Abstract

 Background: The diagnostic reference level (DRL) is measured with different methods in the common Computed tomography (CT) exams, but it has not been measured through the Size-Specific Dose Estimate (SSDE) method in Iran, yet. Objective: This study aimed to calculate the local DRL (LDRL) using the new Quality Control-Based Dose Survey Method (QC) and patients’ effective diameter (MQC) and compare them with a data collection method (DC) as well as local national DRLs (NDRL). Material and Methods: In this cross-sectional study, LDRL, based on the third quartile of volumetric computed tomography dose index (CTDIvol) and dose length product (DLP) values, was calculated for the four common CT examinations in four CT scan centers affiliated with Shiraz University of Medical Sciences by DC, QC and MQC methods. The CTDIvol of each patient for each CT exam calculated with three methods was compared with paired t-test. Also, the LDRL using MQC method was compared with other national DRL studies. Results: There was a significant difference between the CTDIvol values calculated with MQC and QC in all four examinations (P <0. 001). The LDRL based on CTDIvol obtained by the MQC method for head, sinus, chest, abdomen, and pelvis were (50, 18, 15, 19) mGy, respectively, and the calculated DLP values were also (735, 232, 519, 984) mGy. cm. Conclusion: In MQC, LDRL based on CTDIvol was calculated with a mean difference percentage of (19. 2 ± 11. 6)% and (27. 1 ± 8. 1)% as compared to the QC and DC methods, respectively. This difference resulted from the use of the SSDE method and dose accuracy in the QC dose survey.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Tabesh, Jalal, Mahdavi, Maziyar, Haddadi, Gholamhasan, Ravanfar Haghighi, Rezvan, & JALLI, REZA. (2021). Determination of Diagnostic Reference Level (DRL) in Common Computed Tomography Examinations with the Modified Quality Control-Based Dose Survey Method in Four University Centers: A Comparison of Methods. JOURNAL OF BIOMEDICAL PHYSICS AND ENGINEERING, 11(4), 447-458. SID. https://sid.ir/paper/698134/en

    Vancouver: Copy

    Tabesh Jalal, Mahdavi Maziyar, Haddadi Gholamhasan, Ravanfar Haghighi Rezvan, JALLI REZA. Determination of Diagnostic Reference Level (DRL) in Common Computed Tomography Examinations with the Modified Quality Control-Based Dose Survey Method in Four University Centers: A Comparison of Methods. JOURNAL OF BIOMEDICAL PHYSICS AND ENGINEERING[Internet]. 2021;11(4):447-458. Available from: https://sid.ir/paper/698134/en

    IEEE: Copy

    Jalal Tabesh, Maziyar Mahdavi, Gholamhasan Haddadi, Rezvan Ravanfar Haghighi, and REZA JALLI, “Determination of Diagnostic Reference Level (DRL) in Common Computed Tomography Examinations with the Modified Quality Control-Based Dose Survey Method in Four University Centers: A Comparison of Methods,” JOURNAL OF BIOMEDICAL PHYSICS AND ENGINEERING, vol. 11, no. 4, pp. 447–458, 2021, [Online]. Available: https://sid.ir/paper/698134/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button