مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

113
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

62
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Relationship between the filter type and blood flow rate and, dialysis adequacy in hemodialysis patients

Pages

  94-98

Abstract

 Context: One of the main factors associated with the death of chronic renal failure patients is Dialysis adequacy. Aims: The present study aimed to investigate the relationship between Filter type and Blood flow rate with Dialysis adequacy in Hemodialysis patients referring to educational hospitals of Mazandaran University of Medical Sciences in 2016. Setting and Design: This correlational study was performed in 2016 in educational hospitals of Mazandaran University of Medical Sciences. Materials and Methods: This study was performed on 185 Hemodialysis patients. Sampling was done using simple random sampling. The inclusion criteria included at least 6 months of hemodialysis history and two sessions of dialysis per week. Demographic data, as well as information on the Filter type and Blood flow rate, were collected using a questionnaire. Dialysis adequacy is generally measurable by two methods of urea reduction ratio (URR) and K or urea clearance, T or time of dialysis, and V, or volume of urea distribution in the body (KT/V) (K or urea clearance). Statistical Analysis Used: Data were described with mean, standard deviation, and frequency and analyzed using Chi-square and Fisher’ s exact tests. Results: Out of a total of 185 patients, 101 patients were male and 84 were female, with a mean age of 57. 2 ± 0. 7 years. The Dialysis adequacy in high-flux and low-flux filters was, respectively, 79% and 1. 5% based on the KT/V index and 70. 6% and 0% according to the URR index. A statistically significant relationship was found between the Filter type and Blood flow rate with both KT/V and URR criteria (P < 0. 001). Conclusion: It is recommended to use high-flux filters with high Blood flow rate to improve Dialysis adequacy in patients with hemodialysis. However, other factors affecting Dialysis adequacy should be considered.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Nezami Ghale Noee, Mohsen, HASANI, JALIL, & ERFANPOOR, SAEED. (2020). Relationship between the filter type and blood flow rate and, dialysis adequacy in hemodialysis patients. JOURNAL OF NURSING AND MIDWIFERY SCIENCES, 7(2), 94-98. SID. https://sid.ir/paper/700066/en

    Vancouver: Copy

    Nezami Ghale Noee Mohsen, HASANI JALIL, ERFANPOOR SAEED. Relationship between the filter type and blood flow rate and, dialysis adequacy in hemodialysis patients. JOURNAL OF NURSING AND MIDWIFERY SCIENCES[Internet]. 2020;7(2):94-98. Available from: https://sid.ir/paper/700066/en

    IEEE: Copy

    Mohsen Nezami Ghale Noee, JALIL HASANI, and SAEED ERFANPOOR, “Relationship between the filter type and blood flow rate and, dialysis adequacy in hemodialysis patients,” JOURNAL OF NURSING AND MIDWIFERY SCIENCES, vol. 7, no. 2, pp. 94–98, 2020, [Online]. Available: https://sid.ir/paper/700066/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button