مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

204
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

84
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETERMINATION OF 2-OCTANONE IN BIOLOGICAL SAMPLES USING LIQUID–LIQUID MICROEXTRACTIONS FOLLOWED BY GAS CHROMATOGRAPHY–FLAME IONIZATION DETECTION

Pages

  121-128

Abstract

 Background: Analysis of chemicals in biological fluids is required in many areas of medical sciences. Rapid, highly efficient, and reliable dispersive and air assisted liquid–liquid microextraction methods followed by GAS CHROMATOGRAPHY-flame ionization detection were developed for the extraction, preconcentration, and determination of 2-OCTANONE in human PLASMA and URINE samples.Methods: Proteins of PLASMA samples are precipitated by adding methanol and URINE sample is diluted with water prior to performing the microextraction procedure. Fine organic solvent droplets are formed by repeated suction and injection of the mixture of sample solution and extraction solvent into a test tube with a glass syringe. After extraction, phase separation is performed by centrifuging and the enriched analyte in the sedimented organic phase is determined by the separation system. The main factors influencing the extraction efficiency including extraction solvent type and volume, salt addition, pH, and extraction times are investigated.Results: Under the optimized conditions, the proposed method showed good precision (relative standard deviation less than 7%). Limit of detection and lower limit of quantification for 2-OCTANONE were obtained in the range of 0.1-0.5 mg mL-1. The linear ranges were 0.5-500 and 0.5-200 mg mL-1 in PLASMA and URINE, respectively (r2≥0.9995). Enrichment factors were in the range of 13-37. Good recoveries (55-86%) were obtained for the spiked samples.Conclusion: Preconcentration methods coupled with GC analysis were developed and could be used to monitor 2-OCTANONE in BIOLOGICAL SAMPLEs.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    JOUYBAN, ABOLGHASEM, ABBASPOUR, MARYAM, FARAJZADEH, MIR ALI, & KHOUBNASABJAFARI, MARYAM. (2017). DETERMINATION OF 2-OCTANONE IN BIOLOGICAL SAMPLES USING LIQUID–LIQUID MICROEXTRACTIONS FOLLOWED BY GAS CHROMATOGRAPHY–FLAME IONIZATION DETECTION. PHARMACEUTICAL SCIENCES, 23(2), 121-128. SID. https://sid.ir/paper/700396/en

    Vancouver: Copy

    JOUYBAN ABOLGHASEM, ABBASPOUR MARYAM, FARAJZADEH MIR ALI, KHOUBNASABJAFARI MARYAM. DETERMINATION OF 2-OCTANONE IN BIOLOGICAL SAMPLES USING LIQUID–LIQUID MICROEXTRACTIONS FOLLOWED BY GAS CHROMATOGRAPHY–FLAME IONIZATION DETECTION. PHARMACEUTICAL SCIENCES[Internet]. 2017;23(2):121-128. Available from: https://sid.ir/paper/700396/en

    IEEE: Copy

    ABOLGHASEM JOUYBAN, MARYAM ABBASPOUR, MIR ALI FARAJZADEH, and MARYAM KHOUBNASABJAFARI, “DETERMINATION OF 2-OCTANONE IN BIOLOGICAL SAMPLES USING LIQUID–LIQUID MICROEXTRACTIONS FOLLOWED BY GAS CHROMATOGRAPHY–FLAME IONIZATION DETECTION,” PHARMACEUTICAL SCIENCES, vol. 23, no. 2, pp. 121–128, 2017, [Online]. Available: https://sid.ir/paper/700396/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button