مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

234
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

133
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

EVALUATION OF EFFECT OF DIFFERENT COMPUTED TOMOGRAPHY SCANNING PROTOCOLS ON HOUNSFIELD UNIT AND ITS IMPACT ON DOSE CALCULATION BY TREATMENT PLANNING SYSTEM

Pages

  149-154

Abstract

 Introduction: In radiotherapy TREATMENT PLANNING SYSTEM (TPS), basic input is the data from COMPUTED TOMOGRAPHY (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact on dose calculation. This study was carried out to analyse the effect of different tube voltages on HU for various tissue substitutes in PHANTOM and their dosimetric impact on dose calculation in TPS due to variation in HU–relative electron density (RED) calibration curves.Materials and Methods: HU for different density materials was obtained from CT images of the PHANTOM acquired at various tube voltages. HU-RED calibration curves were drawn from CT images with various tissue substitutes acquired at different tube voltages used to quantify the error in dose calculation for different algorithms. Doses were calculated on CT images acquired at 120 kVp and by applying CT number to RED curve obtained from 80, 100, 120, and 140 kVp voltages.Results: No significant variation was observed in HU of different density materials for various kVp values. Doses calculated with applying different HU-RED calibration curves were well within 1%.Conclusion: Variation in doses calculated by algorithms with various HU-RED calibration curves was found to be well within 1%. Therefore, it can be concluded that clinical practice of using the standard HU-RED calibration curve by a 120 kVp CT acquisition technique is viable.

Cites

References

  • No record.
  • Cite

    APA: Copy

    MAHUR, MAMTA, GURJAR, OM PRAKASH, GROVER, R.K., NEGI, P.S., SHARMA, RICHA, SINGH, ANSHU, & SINGH, MUNENDRA. (2017). EVALUATION OF EFFECT OF DIFFERENT COMPUTED TOMOGRAPHY SCANNING PROTOCOLS ON HOUNSFIELD UNIT AND ITS IMPACT ON DOSE CALCULATION BY TREATMENT PLANNING SYSTEM. IRANIAN JOURNAL OF MEDICAL PHYSICS, 14(3), 149-154. SID. https://sid.ir/paper/701486/en

    Vancouver: Copy

    MAHUR MAMTA, GURJAR OM PRAKASH, GROVER R.K., NEGI P.S., SHARMA RICHA, SINGH ANSHU, SINGH MUNENDRA. EVALUATION OF EFFECT OF DIFFERENT COMPUTED TOMOGRAPHY SCANNING PROTOCOLS ON HOUNSFIELD UNIT AND ITS IMPACT ON DOSE CALCULATION BY TREATMENT PLANNING SYSTEM. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2017;14(3):149-154. Available from: https://sid.ir/paper/701486/en

    IEEE: Copy

    MAMTA MAHUR, OM PRAKASH GURJAR, R.K. GROVER, P.S. NEGI, RICHA SHARMA, ANSHU SINGH, and MUNENDRA SINGH, “EVALUATION OF EFFECT OF DIFFERENT COMPUTED TOMOGRAPHY SCANNING PROTOCOLS ON HOUNSFIELD UNIT AND ITS IMPACT ON DOSE CALCULATION BY TREATMENT PLANNING SYSTEM,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 14, no. 3, pp. 149–154, 2017, [Online]. Available: https://sid.ir/paper/701486/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button