مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

270
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

169
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE DOSIMETRIC EFFECTS OF DIFFERENT MULTILEAF COLLIMATOR WIDTHS ON PHYSICAL DOSE DISTRIBUTIONS

Pages

  12-18

Abstract

 Introduction: Geometric changes in the MULTILEAF COLLIMATOR (MLC) led to dosimetric considerations in INTENSITY-MODULATED RADIATION THERAPY (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical DOSE DISTRIBUTIONs for IMRT plans.Materials and Methods: Forty-two IMRT plans based on different MLC devices were generated and analyzed to study the effect of MLC width on plan quality.Results: Improvements in IMRT plan quality using 0.4 cm leaf width in comparison with 1 cm leaf width were evaluated. The 0.4 cm leaf-based plans resulted in significantly higher Dmean, D98%, D95%, D5%, and V95 (58.86 Gy, 95.11%, 96.57%, 104%, and 97.92%, respectively) compared to the 1 cm leaf plans (58.66 Gy, 92.56%, 94.56%, 104.14%, and 95.72%, respectively). Conformation number (CN) for planning target volume in 0.4 cm leaf plans was significantly higher than the 1 cm leaf plans (0.74 vs.0.67; P<0.05). In addition, the 0.4 cm leaf plans significantly improved dose homogeneity compared to the 1 cm leaf plans (1.08 vs.1.10; P<0.05). We found that 0.4 cm leaf width significantly decreased the integral dose to normal tissue compared to the 1 cm leaf width (from 56.09 to 49.46 Gy.Kg P<0.05).conclusion: No significant clinical differences were observed between the two plans for a serially functioning tissue, while the differences in mean doses were statistically significant for parallel functioning normal tissues.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ATTALLA, EHAB M., & ELDESOKY, ISMAIL. (2018). THE DOSIMETRIC EFFECTS OF DIFFERENT MULTILEAF COLLIMATOR WIDTHS ON PHYSICAL DOSE DISTRIBUTIONS. IRANIAN JOURNAL OF MEDICAL PHYSICS, 15(1), 12-18. SID. https://sid.ir/paper/727655/en

    Vancouver: Copy

    ATTALLA EHAB M., ELDESOKY ISMAIL. THE DOSIMETRIC EFFECTS OF DIFFERENT MULTILEAF COLLIMATOR WIDTHS ON PHYSICAL DOSE DISTRIBUTIONS. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2018;15(1):12-18. Available from: https://sid.ir/paper/727655/en

    IEEE: Copy

    EHAB M. ATTALLA, and ISMAIL ELDESOKY, “THE DOSIMETRIC EFFECTS OF DIFFERENT MULTILEAF COLLIMATOR WIDTHS ON PHYSICAL DOSE DISTRIBUTIONS,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 15, no. 1, pp. 12–18, 2018, [Online]. Available: https://sid.ir/paper/727655/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button