Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

111
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

75
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

OPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking

Pages

  58-62

Abstract

 Purpose: To determine topographic and aberrometric changes after Accelerated cross-linking (ACXL; 18 mW/cm2 for 5 min) as measured with OPD Scan III (Nidek Inc., Tokyo, Japan) and their Repeatability in patients with mild and moderate keratoconus (KCN). Methods: In this prospective study, 25 eyes with mild KCN [Ksteep ¼ 47. 24 ± 3. 11 diopter (D)] and 20 moderate cases (Ksteep ¼ 52. 86 ± 4. 39 D) were examined under Mesopic conditions (20 lux) twice, 30e45 min apart, at baseline and 6 and 12 months afterwards. Extracted indices were Ksteep, Kflat, ocular and corneal irregularity, ocular and corneal total higher order aberrations (HOAs), coma, trefoil, and spherical aberration (SA). Repeatability index (RI) and intraclass correlation coefficients (ICCs) were determined. Results: In mild cases, Ksteep and corneal irregularity had lower RI, but Kflat and ocular irregularity had higher RI (all P > 0. 050) at 1 year. The RI for ocular total HOAs, coma, and SA decreased and showed no significant change for trefoil (all P > 0. 050). Moderate cases showed nonsignificant increases in RI for Ksteep, Kflat, ocular and corneal irregularity (all P > 0. 050), and all aberrometry indices, and significant increases in RI for ocular coma (P ¼ 0. 046) and corneal trefoil (P ¼ 0. 037). At 1 year, ICC was >0. 75 for all indices except ocular and corneal trefoil (ICC ¼ 0. 613 and 0. 390) in moderate cases. Conclusions: At one year after ACXL, OPD Scan III showed acceptable Repeatability in mild cases. In moderate cases, topographic indices had acceptable Repeatability but poorer compared to the mild group. Overall, ocular HOAs showed better Repeatability than corneal ones. These changes should be considered in the interpretation of measurements.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ASGARI, SOHEILA, & HASHEMI, HASSAN. (2018). OPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking. JOURNAL OF CURRENT OPHTHALMOLOGY, 30(1), 58-62. SID. https://sid.ir/paper/761518/en

    Vancouver: Copy

    ASGARI SOHEILA, HASHEMI HASSAN. OPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking. JOURNAL OF CURRENT OPHTHALMOLOGY[Internet]. 2018;30(1):58-62. Available from: https://sid.ir/paper/761518/en

    IEEE: Copy

    SOHEILA ASGARI, and HASSAN HASHEMI, “OPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking,” JOURNAL OF CURRENT OPHTHALMOLOGY, vol. 30, no. 1, pp. 58–62, 2018, [Online]. Available: https://sid.ir/paper/761518/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top