Title

Application of Electrosurgical Units by Operating Room Personnel: Development and Psychometric Testing of an Instrument

Pages

  0-0

Abstract

 Background: Today, Electrosurgical Units are an indispensable part of surgeries. Yet, inappropriate application of this equipment can result in dire consequences for both the patient and the surgical team. Objectives: The present study aimed at developing the psychometric properties of a checklist to evaluate the application of electrosurgery units by Operating Room personnel. Methods: The present methodological study was performed in two stages: first, the items of the checklist were developed based on a literature review and search in relevant websites; and second, the psychometric properties of the checklist were measured using the methods to evaluate face, content, and construct validities. The reliability was measured through an assessment of the internal consistency of the checklist, based on the degree of inter-rater agreement. To assess construct validity, the researchers compared known groups; 40 surgeries were observed in two university hospitals in the intervention and control groups. Results: The content validity index (CVI) of all the items was over 0. 79. The average CVI (S-CVI/Ave) of the checklist with 32 items was 0. 97. The results of the Wilcoxon test showed that the posttest performance scores of the personnel in the intervention group were significantly higher than their pretest scores (P value = 0. 005). The internal consistency (the Kuder-Richardson coefficient) of the checklist was 0. 66. Conclusions: Due to the great importance of appropriate application of electrosurgery units, a reliable instrument is needed to assess personnel’ s performance in this area. The results of the current study showed that the present instrument is sufficiently valid and reliable to evaluate the application of Electrosurgical Units by the Operating Room personnel.

Cites

References

  • No record.
  • Cite

    APA: Copy

    TORABIZADEH, CAMELLIA, Fereidouni, Armin, AMIRI, MINA, & Moayedi, Seyed Alireza. (2020). Application of Electrosurgical Units by Operating Room Personnel: Development and Psychometric Testing of an Instrument. SHIRAZ E MEDICAL JOURNAL, 21(2), 0-0. SID. https://sid.ir/paper/761581/en

    Vancouver: Copy

    TORABIZADEH CAMELLIA, Fereidouni Armin, AMIRI MINA, Moayedi Seyed Alireza. Application of Electrosurgical Units by Operating Room Personnel: Development and Psychometric Testing of an Instrument. SHIRAZ E MEDICAL JOURNAL[Internet]. 2020;21(2):0-0. Available from: https://sid.ir/paper/761581/en

    IEEE: Copy

    CAMELLIA TORABIZADEH, Armin Fereidouni, MINA AMIRI, and Seyed Alireza Moayedi, “Application of Electrosurgical Units by Operating Room Personnel: Development and Psychometric Testing of an Instrument,” SHIRAZ E MEDICAL JOURNAL, vol. 21, no. 2, pp. 0–0, 2020, [Online]. Available: https://sid.ir/paper/761581/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button