Title

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Pages

  11701-11708

Abstract

 Background: Pulmonary complications following Valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and Functional capacity to Positive End-Expiratory Pressure device in patients who underwent Valvular heart surgery. Materials and Methods: Thirty males and females who underwent Valvular heart surgery aged from 12-18 years old and recruited from the National Heart Institute enrolled in this study. They were assigned into two matched groups: the intervention group consisted of 15 patients, received Positive End-Expiratory Pressure (PEEP) with the mouthpiece in addition to routine chest physiotherapy program; the control group consisted of 15 patients, received routine chest physiotherapy program only. The program continued for four weeks, then the results compared in two groups. Results: According to the results of data analysis, there was a statistically significant difference between pretreatment and post-treatment data in both groups regarding Inspiratory muscle strength and Functional capacity (p< 0. 001). There was no significant difference between groups regarding post-treatment data of Maximal Inspiratory Pressure (MIP), and VO2 max (p=0. 084, p=0. 325), respectively. Conclusion: According to the results, expiratory training using a PEEP device with mouthpiece improved Inspiratory muscle strength and Functional capacity after Valvular heart surgery.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Mabrouk, Mohamed Ibrahim, Mehrem, Elsayed Said, Kamel, Roshdy Mohamed, Abdalla, Eman Elsayed, & Mohamed Ali, Shymaa. (2020). Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery. INTERNATIONAL JOURNAL OF PEDIATRICS, 8(8 (80)), 11701-11708. SID. https://sid.ir/paper/773984/en

    Vancouver: Copy

    Mabrouk Mohamed Ibrahim, Mehrem Elsayed Said, Kamel Roshdy Mohamed, Abdalla Eman Elsayed, Mohamed Ali Shymaa. Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery. INTERNATIONAL JOURNAL OF PEDIATRICS[Internet]. 2020;8(8 (80)):11701-11708. Available from: https://sid.ir/paper/773984/en

    IEEE: Copy

    Mohamed Ibrahim Mabrouk, Elsayed Said Mehrem, Roshdy Mohamed Kamel, Eman Elsayed Abdalla, and Shymaa Mohamed Ali, “Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery,” INTERNATIONAL JOURNAL OF PEDIATRICS, vol. 8, no. 8 (80), pp. 11701–11708, 2020, [Online]. Available: https://sid.ir/paper/773984/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button