مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,121
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

PREPARATION OF HEME CONTROL FOR CELLULOSE ACETATE ELECTROPHORESIS

Pages

  53-58

Abstract

 Background and Objectives To avoid laboratory errors in the detection of hemoglobinopathies, a control sample containing HEMOGLOBIN (Hb) A,F,S or C should run with each set of samples.The aim of this project was to prepare a lyophilized heme control for the CELLULOSE ACETATE ELECTROPHORESIS.Materials and MethodsAfter lysing the red blood cells, the hemolysate was centrifuged at 25000 rpm. The clear red supernatant was diluted with drabkin reagent to 20-30 gr/L and Hb was converted to cyanomethemoglobin. After adding sucrose and preservatives, the hemolysate was passed through milipore filter (0.45 µm) and then aliqouted and lyophilized.ResultsIn this project three heme control samples were prepared. The first sample contains Hbs A,F,D or G ,the second one contains Hbs A,S, and the third contains Hb A,F. Although the amount of potassium cyanide used is 10 times less than other methods , the stability is more than 6 months at 4oC; moreover, and the electrophoretic patterns have good resolution and the obtained CV and SD show good reproducibility.ConclusionsThe preparation method in this project is simple, reliable, cost effective and in comparison with other methods has less amount of potassium cyanide; therefore, it is safe for the laboratory staff.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HOSSEINI GOUHARI, L., NOORMOHAMMADI, E., & ATAR CHI, Z.. (2005). PREPARATION OF HEME CONTROL FOR CELLULOSE ACETATE ELECTROPHORESIS. THE SCIENTIFIC JOURNAL OF IRANIAN BLOOD TRANSFUSION ORGANIZATION (KHOON), 2(3), 53-58. SID. https://sid.ir/paper/78562/en

    Vancouver: Copy

    HOSSEINI GOUHARI L., NOORMOHAMMADI E., ATAR CHI Z.. PREPARATION OF HEME CONTROL FOR CELLULOSE ACETATE ELECTROPHORESIS. THE SCIENTIFIC JOURNAL OF IRANIAN BLOOD TRANSFUSION ORGANIZATION (KHOON)[Internet]. 2005;2(3):53-58. Available from: https://sid.ir/paper/78562/en

    IEEE: Copy

    L. HOSSEINI GOUHARI, E. NOORMOHAMMADI, and Z. ATAR CHI, “PREPARATION OF HEME CONTROL FOR CELLULOSE ACETATE ELECTROPHORESIS,” THE SCIENTIFIC JOURNAL OF IRANIAN BLOOD TRANSFUSION ORGANIZATION (KHOON), vol. 2, no. 3, pp. 53–58, 2005, [Online]. Available: https://sid.ir/paper/78562/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button