مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

137
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

53
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Seminar Paper

Title

NUMERICAL INVESTIGATION OF ANTEGRADE FLOW EFFECTS ON FLOW PULSATION IN FONTAN OPERATION USING A MULTISCALE MODEL

Pages

  -

Keywords

Not Registered.

Abstract

 THIS STUDY CONSIDERS BLOOD FLOW IN TOTAL CAVOPULMONARY CONNECTION (TCPC) MORPHOLOGY, CREATED IN FONTAN SURGICAL PROCEDURE IN PATIENTS WITH A SINGLE VENTRICLE HEART DISEASE. ORDINARY PROCESS OF TCPC OPERATION REDUCES PULMONARY BLOOD FLOW PULSATILITY; SINCE THE RIGHT VENTRICLE BEING BYPASSED. THIS REDUCTION MAY LIMIT THE LONG TERM OUTCOME OF FONTAN CIRCULATION. THERE IS AN IDEA OF INCREASING PULMONARY FLOW PULSATIONS BY KEEPING MAIN PULMONARY ARTERY (MPA) PARTIALLY OPEN WHILE IT WAS CLOSED IN ORDINARY TCPC OPERATION. THE PURPOSE OF THE PRESENT STUDY IS TO VERIFY THE EFFECTS OF ANTEGRADE FLOW (AF) COMING THROUGH STENOSED MPA ON PULMONARY FLOW PULSATIONS, BY MEANS OF COMPUTATIONAL FLUID DYNAMICS (CFD). THE 3-D GEOMETRY IS RECONSTRUCTED FROM CT ANGIOGRAPHY SCAN OF A PATIENT WHO HAS UNDERGONE AN ORDINARY TCPC PROCEDURE. THE STENOSED MPA OR PULMONARY STENOSIS (PS) IS VIRTUALLY ADDED TO THE ORIGINAL GEOMETRY. INLET VELOCITY PROFILES ARE OBTAINED FROM ECHOCARDIOGRAPHY DATA OF THE SAME PATIENT. AF PROFILE IN A CARDIAC CYCLE IS OBTAINED FROM A GENERAL PRESSURE CYCLE OF LEFT VENTRICLE, ASSUMING A LINEAR RELATIONSHIP BETWEEN PRESSURE GRADIENT AND FLOW RATE IN PS. WE APPLIED A 3D-1D COUPLED METHOD TO SIMULATE BLOOD FLOW IN THIS SITUATION MORE PRECISELY. THE RESULTS SHOW THAT ADDING AF INCREASES PULSATILITY INDEX (PI) IN BOTH LEFT AND RIGHT PULMONARY ARTERY (LPA AND RPA RESPECTIVELY). MOREOVER, ADDING AF LEADS TO AN INCREASE IN ENERGY LOSS. IT ALSO INCREASES THE PULMONARY-TO-SYSTEMIC FLOW RATIO LEADING TO INCREASE IN TOTAL CARDIAC FLOW RATE AND HENCE HEART POWER

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Monjezi, Mojdeh, Ghoreyshi, Mostafa, Saidi, Mohammad Said, FIROOZABADI, BAHAR, & Navabi, Ali. (2012). NUMERICAL INVESTIGATION OF ANTEGRADE FLOW EFFECTS ON FLOW PULSATION IN FONTAN OPERATION USING A MULTISCALE MODEL. IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING. SID. https://sid.ir/paper/926416/en

    Vancouver: Copy

    Monjezi Mojdeh, Ghoreyshi Mostafa, Saidi Mohammad Said, FIROOZABADI BAHAR, Navabi Ali. NUMERICAL INVESTIGATION OF ANTEGRADE FLOW EFFECTS ON FLOW PULSATION IN FONTAN OPERATION USING A MULTISCALE MODEL. 2012. Available from: https://sid.ir/paper/926416/en

    IEEE: Copy

    Mojdeh Monjezi, Mostafa Ghoreyshi, Mohammad Said Saidi, BAHAR FIROOZABADI, and Ali Navabi, “NUMERICAL INVESTIGATION OF ANTEGRADE FLOW EFFECTS ON FLOW PULSATION IN FONTAN OPERATION USING A MULTISCALE MODEL,” presented at the IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING. 2012, [Online]. Available: https://sid.ir/paper/926416/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button