مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

195
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation of Risk of Secondary Thyroid Cancer Caused by Neutron Dose Equivalent from Brain Tumor 3D-Conformal Radiation Therapy (3D-CRT)

Author(s)

Elmtalab Soheil | ABEDI IRAJ | Choopan Dastjerdi Mohammad Hosein | SHANEI AHMAD | Issue Writer Certificate 

Pages

  569-574

Abstract

 Background: Thyroid cancer is one of the most common secondary malignancies as a result of receiving therapeutic doses to the head and neck. In this study, the probability of secondary Thyroid cancer risk due to neutron contamination of 15 MV Siemens Linear Accelerator (LINAC) in brain tumor 3D-Conformal Radiation therapy (3D-CRT) was calculated. Methods: Neutron fluence and neutron dose were measured at different points at the treatment table using an energy-independent neutron detector consisting of a sphere moderator and a Boron Trifluoride (BF3) counter, and the neutron dose equivalent to the Thyroid was determined to calculate the probability of secondary cancer risk. Findings: The neutron dose equivalent was obtained at the central axis (0. 304 mSv/Gy) and at 4 cm (0. 285 mSv/Gy), 15 cm (0. 229 mSv/Gy), 45 cm (0. 125 mSv/Gy), and 150 cm (0. 02 mSv/Gy) inferior. The neutron dose equivalent reaching the Thyroid for the total prescribed dose was 12. 366 mSv. According to that, the probability of secondary Thyroid cancer risk was obtained as 0. 001%. Conclusion: The Thyroid dose in high-energy Radiation therapy of brain tumor cannot cause significant biological damage. Therefore, the risk of secondary Thyroid cancer due to neutron contamination is relatively low.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Elmtalab, Soheil, ABEDI, IRAJ, Choopan Dastjerdi, Mohammad Hosein, & SHANEI, AHMAD. (2020). Evaluation of Risk of Secondary Thyroid Cancer Caused by Neutron Dose Equivalent from Brain Tumor 3D-Conformal Radiation Therapy (3D-CRT). JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), 38(586 ), 569-574. SID. https://sid.ir/paper/952569/en

    Vancouver: Copy

    Elmtalab Soheil, ABEDI IRAJ, Choopan Dastjerdi Mohammad Hosein, SHANEI AHMAD. Evaluation of Risk of Secondary Thyroid Cancer Caused by Neutron Dose Equivalent from Brain Tumor 3D-Conformal Radiation Therapy (3D-CRT). JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S)[Internet]. 2020;38(586 ):569-574. Available from: https://sid.ir/paper/952569/en

    IEEE: Copy

    Soheil Elmtalab, IRAJ ABEDI, Mohammad Hosein Choopan Dastjerdi, and AHMAD SHANEI, “Evaluation of Risk of Secondary Thyroid Cancer Caused by Neutron Dose Equivalent from Brain Tumor 3D-Conformal Radiation Therapy (3D-CRT),” JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), vol. 38, no. 586 , pp. 569–574, 2020, [Online]. Available: https://sid.ir/paper/952569/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button