مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

269
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?

Pages

  25-32

Keywords

Deviation index (DI) 

Abstract

 Background: Clinical application of the test results are profoundly influenced by laboratory errors. Nowadays, the best way to evaluate the performance of a method is to determine its Sigma scale according to total allowable error (TEa) and analytical errors, including random and systematic errors. In this study, the performance of the measuring kits for Biochemical analytes belonging to Pars Azmoon Company, as the most commonly used kits in Iran, was evaluated by determining their deviation index (DI) and Sigma scale. Materials and methods: During the years 2013-17 and the 15th to 28th runs of the external quality assessment program (EQAP), commercial control materials were sent to about 2000 participating laboratories in each period. Based on the results of measuring the Biochemical analytes by these laboratories, Method performance of measuring methods was determined according to DI and Sigma scale. For determining Sigma scale, two different TEa was used. Results: Based on the TEa introduced by the reference health laboratory of Iran, among the 21 analyzed analytes, DI of the 7, 11, and 3 analytes were acceptable (DI up to 2. 0) for 100%, 90% and less than 90% of the reported results, respectively. In Sigma scale evaluation of these methods according to TEa of reference health laboratory of Iran and CLIA (Clinical Laboratory Improvement Amendments), 13 and 12 measuring methods were acceptable (sigma of at least 2. 0), respectively. Conclusion: Due to the importance of the test results in medical decision making, it is necessary to improve the performance of measuring methods.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Atabi, Fereshteh, & MOHAMMADI, REZA. (2020). Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?. MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY, 30(1 ), 25-32. SID. https://sid.ir/paper/964422/en

    Vancouver: Copy

    Atabi Fereshteh, MOHAMMADI REZA. Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?. MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY[Internet]. 2020;30(1 ):25-32. Available from: https://sid.ir/paper/964422/en

    IEEE: Copy

    Fereshteh Atabi, and REZA MOHAMMADI, “Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?,” MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY, vol. 30, no. 1 , pp. 25–32, 2020, [Online]. Available: https://sid.ir/paper/964422/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button