مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,302
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION OF X-RAY FACTORS AND ITS EFFECT ON RADIOLOGY DEPARTMENT STAFF AT ARMY HOSPITALS IN TEHRAN IN THE YEAR 1385

Pages

  71-73

Abstract

 History and goal: Knowledge of X-Ray related factors connected with individual dosimeter can be beneficial in diminishing the rate of x-ray intake. Keeping in mind the above mentioned goal, we planned and prepared this study with the help of all radiology staff of the hospital.Materials and procedures: This research is a descriptive, analytic and a sectional study which was performed in the year 1385. All radiology staff of the army hospitals in Tehran was bulk examples. A check list and a questionnaire form were used to collect data and information. We also made use of SPSS software for data purpose.Achievements: Results obtained in this study indicate that individual maximum dose received individually was 29.0 MILISILVERT; the rate of this dose was seen in persons who lacked University education. And a minimum dose received was 0.05 millisiurt which was received by individuals who were less than 30 hours in contact with the preparation of unison. Many medical tests were performed at the following army hospitals: Golestan, 502, 204 and Mostafa Khomeini hospitals. The X-Ray rate at the mentioned hospitals was 100%.Results obtained: Dose received by all individuals as classified parameters expected was standard and acceptable. Therefore organizing X-ray safety workoshops especially in connection with promoting security level of unison production staff at all centers is an absolute must.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    EYVAZ ZADEH, N., KHOUSHDEL, ALI REZA, AZMA, K., & FOULAD VAND, L.. (2008). EVALUATION OF X-RAY FACTORS AND ITS EFFECT ON RADIOLOGY DEPARTMENT STAFF AT ARMY HOSPITALS IN TEHRAN IN THE YEAR 1385. ANNALS OF MILITARY AND HEALTH SCIENCES RESEARCH, 6(1 (SERIAL NUMBER 21)), 71-73. SID. https://sid.ir/paper/96726/en

    Vancouver: Copy

    EYVAZ ZADEH N., KHOUSHDEL ALI REZA, AZMA K., FOULAD VAND L.. EVALUATION OF X-RAY FACTORS AND ITS EFFECT ON RADIOLOGY DEPARTMENT STAFF AT ARMY HOSPITALS IN TEHRAN IN THE YEAR 1385. ANNALS OF MILITARY AND HEALTH SCIENCES RESEARCH[Internet]. 2008;6(1 (SERIAL NUMBER 21)):71-73. Available from: https://sid.ir/paper/96726/en

    IEEE: Copy

    N. EYVAZ ZADEH, ALI REZA KHOUSHDEL, K. AZMA, and L. FOULAD VAND, “EVALUATION OF X-RAY FACTORS AND ITS EFFECT ON RADIOLOGY DEPARTMENT STAFF AT ARMY HOSPITALS IN TEHRAN IN THE YEAR 1385,” ANNALS OF MILITARY AND HEALTH SCIENCES RESEARCH, vol. 6, no. 1 (SERIAL NUMBER 21), pp. 71–73, 2008, [Online]. Available: https://sid.ir/paper/96726/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button