مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

3,067
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INVESTIGATION OF THE SPATIAL RESOLUTION AND FIELD OF VIEW WITH CHANGE OF MAGNIFICATION IN VRX CT

Pages

  35-45

Keywords

VARIABLE RESOLUTION X-RAY (VRX) CTQ3

Abstract

 Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various SPATIAL RESOLUTIONs. In a VRX CT scanner, the SPATIAL RESOLUTION increases at the cost of reduction in the FIELD OF VIEW (FOV). An important factor that limits the SPATIAL RESOLUTION of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident angle.Material and Methods: To investigate the SPATIAL RESOLUTION and the FOV in VRX CT, we used the numerical parameters of an actual VRX CT scanner. The effects of decreasing the focal spot size and optimizing magnification on the SPATIAL RESOLUTION and the FOV of the system were studied theoretically.Results: The focal spot size was found to greatly limit the SPATIAL RESOLUTION of the VRX CT at the small incident angles. By decreasing the focal spot size, the SPATIAL RESOLUTION was comparatively improved. Optimization of the SYSTEM MAGNIFICATION without decreasing the focal spot size could greatly increase the SPATIAL RESOLUTION of the system. After optimization of magnification, the FOV of the system decreased significantly.Discussion and Conclusion: The SPATIAL RESOLUTION of the system after optimizing the magnification increased from 7.5 to more than 35 cycles/mm and also the effect of the focal spot no longer limited the SPATIAL RESOLUTION at incident angles smaller than 13o. The disadvantage of optimization of magnification was a great decrease in the FOV of the system. The optimization of magnification has the reverse effect on the SPATIAL RESOLUTION and the FOV of the system so at each incident angle, according to the importance of SPATIAL RESOLUTION or FOV, the SYSTEM MAGNIFICATION can be set to lead to the desirable condition.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ARABI, HOSSEIN, KAMALI ASL, ALIREZA, & AGHAMIRI, SEYED MAHMOOD REZA. (2010). INVESTIGATION OF THE SPATIAL RESOLUTION AND FIELD OF VIEW WITH CHANGE OF MAGNIFICATION IN VRX CT. IRANIAN JOURNAL OF MEDICAL PHYSICS, 7(3 (28)), 35-45. SID. https://sid.ir/paper/96944/en

    Vancouver: Copy

    ARABI HOSSEIN, KAMALI ASL ALIREZA, AGHAMIRI SEYED MAHMOOD REZA. INVESTIGATION OF THE SPATIAL RESOLUTION AND FIELD OF VIEW WITH CHANGE OF MAGNIFICATION IN VRX CT. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2010;7(3 (28)):35-45. Available from: https://sid.ir/paper/96944/en

    IEEE: Copy

    HOSSEIN ARABI, ALIREZA KAMALI ASL, and SEYED MAHMOOD REZA AGHAMIRI, “INVESTIGATION OF THE SPATIAL RESOLUTION AND FIELD OF VIEW WITH CHANGE OF MAGNIFICATION IN VRX CT,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 7, no. 3 (28), pp. 35–45, 2010, [Online]. Available: https://sid.ir/paper/96944/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top