مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,900
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CT-BASED BRACHYTHERAPY TREATMENT PLANNING USING MONTE CARLO SIMULATION AIDED BY AN INTERFACE SOFTWARE

Pages

  41-53

Abstract

 Introduction: In BRACHYTHERAPY, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized TREATMENT PLANNING. The usual method for TREATMENT PLANNING of cervix BRACHYTHERAPY uses conventional radiographs in the Manchester system. Nowadays, because of their advantages in locating the source positions and the surrounding tissues, CT and MRI images are replacing conventional radiographs. In this study, we used CT images in Monte Carlo based dose calculation for BRACHYTHERAPY TREATMENT PLANNING, using an INTERFACE SOFTWARE to create the geometry file required in the MCNP code. The aim of using the INTERFACE SOFTWARE is to facilitate and speed up the geometry set-up for simulations based on the patient’s anatomy. This paper examines the feasibility of this method in cervix BRACHYTHERAPY and assesses its accuracy and speed.Material and Methods: For dosimetric measurements regarding the treatment plan, a pelvic phantom was made from polyethylene in which the treatment applicators could be placed. For simulations using CT images, the phantom was scanned at 120 kVp. Using an INTERFACE SOFTWARE written in MATLAB, the CT images were converted into MCNP input file and the simulation was then performed.Results: Using the INTERFACE SOFTWARE, preparation time for the simulations of the applicator and surrounding structures was approximately 3 minutes; the corresponding time needed in the conventional MCNP geometry entry being approximately 1 hour. The discrepancy in the simulated and measured doses to point A was 1.7% of the prescribed dose. The corresponding dose differences between the two methods in rectum and bladder were 3.0% and 3.7% of the prescribed dose, respectively.Comparing the results of simulation using the INTERFACE SOFTWARE with those of simulation using the standard MCNP geometry entry showed a less than 1% difference of the prescribed dose at 67% of the studied points (minimum<0.01%, maximum 4.8%).Discussion and Conclusions: Using the INTERFACE SOFTWARE reduces the overall simulation time. Comparison of the results of the measurements, simulation using the INTERFACE SOFTWARE and simulation using standard MCNP geometry entry shows that the use of tomographic images and transforming them into MCNP input file for dose calculation in BRACHYTHERAPY is feasible and reasonably accurate.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MOSLEMI, VAHID, ESMAILI TORSHABI, AHMAD, MOSLEH SHIRAZI, MOHAMMAD AMIN, FAGHIHI, REZA, MOSALAEI, AHMAD, MEHDIZADEH, SIMIN, & HADAD, KAMAL. (2011). CT-BASED BRACHYTHERAPY TREATMENT PLANNING USING MONTE CARLO SIMULATION AIDED BY AN INTERFACE SOFTWARE. IRANIAN JOURNAL OF MEDICAL PHYSICS, 8(1 (30)), 41-53. SID. https://sid.ir/paper/96992/en

    Vancouver: Copy

    MOSLEMI VAHID, ESMAILI TORSHABI AHMAD, MOSLEH SHIRAZI MOHAMMAD AMIN, FAGHIHI REZA, MOSALAEI AHMAD, MEHDIZADEH SIMIN, HADAD KAMAL. CT-BASED BRACHYTHERAPY TREATMENT PLANNING USING MONTE CARLO SIMULATION AIDED BY AN INTERFACE SOFTWARE. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2011;8(1 (30)):41-53. Available from: https://sid.ir/paper/96992/en

    IEEE: Copy

    VAHID MOSLEMI, AHMAD ESMAILI TORSHABI, MOHAMMAD AMIN MOSLEH SHIRAZI, REZA FAGHIHI, AHMAD MOSALAEI, SIMIN MEHDIZADEH, and KAMAL HADAD, “CT-BASED BRACHYTHERAPY TREATMENT PLANNING USING MONTE CARLO SIMULATION AIDED BY AN INTERFACE SOFTWARE,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 8, no. 1 (30), pp. 41–53, 2011, [Online]. Available: https://sid.ir/paper/96992/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top