Title

Evaluation of direct reading photoionization detector performance under various operational parameters

Pages

  123-128

Abstract

 Background: A hand-held portable direct-reading monitor, including photoionization detector (PID) is renowned for its good sensitivity, considerable dynamic range, and nondestructive vapor detection ability in comparison to the tardy response of the PID in gas Chromatography (GC), which its application has been restricted. In this study, the performance of a PID system (MultiRAE Lite) was evaluated as a replacement of GC in the measurement of Toluene in a dynamic Adsorption system. Methods: The test was done at different relative Humidity levels (30%, 50%, and 80%), Temperatures (21, 30, 40 ° C), and Toluene concentrations (20, 100, 200, and 400 ppm). Results: The PID achieved 48% of all measurements meeting the comparison criterion. The results showed that the performance of the PID could be altered by the variables. The best performance of the PID was at temperature of 21 ° C, the relative Humidity of 50%, and concentration of 200 ppm with the percentage of readings achieving the criterion of comparison to 58%, 54%, and 52%, respectively. The averages of the PID readings (mean ± SD at 200 ppm= 207. 9 ± 8. 7) were higher than the reference method measurements averages (mean ± SD at 200 ppm= 203. 5 ± 5. 8). The regression analysis of the Toluene results from the PID and the reference method results indicated that the measurements were significantly correlated (r 2 = 0. 93). Conclusion: According to the results, the device response is linear. Therefore, the findings are acceptable in Adsorption studies. In this way, the measurement of the sample concentration should be performed using the same instrument before and after the reactor in order to calculate the Adsorption efficiency.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KHOSHAKHLAGH, AMIR HOSSEIN, GOLBABAEI, FARIDEH, BEYGZADEH, MOJTABA, Carrasco Marin, Francisco, & SHAHTAHERI, SEYED JAMALEDDIN. (2021). Evaluation of direct reading photoionization detector performance under various operational parameters. ENVIRONMENTAL HEALTH ENGINEERING AND MANAGMENT JOURNAL, 8(2), 123-128. SID. https://sid.ir/paper/972364/en

    Vancouver: Copy

    KHOSHAKHLAGH AMIR HOSSEIN, GOLBABAEI FARIDEH, BEYGZADEH MOJTABA, Carrasco Marin Francisco, SHAHTAHERI SEYED JAMALEDDIN. Evaluation of direct reading photoionization detector performance under various operational parameters. ENVIRONMENTAL HEALTH ENGINEERING AND MANAGMENT JOURNAL[Internet]. 2021;8(2):123-128. Available from: https://sid.ir/paper/972364/en

    IEEE: Copy

    AMIR HOSSEIN KHOSHAKHLAGH, FARIDEH GOLBABAEI, MOJTABA BEYGZADEH, Francisco Carrasco Marin, and SEYED JAMALEDDIN SHAHTAHERI, “Evaluation of direct reading photoionization detector performance under various operational parameters,” ENVIRONMENTAL HEALTH ENGINEERING AND MANAGMENT JOURNAL, vol. 8, no. 2, pp. 123–128, 2021, [Online]. Available: https://sid.ir/paper/972364/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button