مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

840
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION OF THE PERFORMANCE OF COMMON KITS FOR THE MEASUREMENT OF CREATININE IN SERUM AND URINE: ARE THE RESULTS OF THESE METHODS SUITABLE FOR CLINICAL USE?

Pages

  162-169

Abstract

 Background: Measuring serum and urine CREATININE level is currently the most common method for assessing renal function. For this purpose, Jaffe’ s method is most commonly used. The inconsistency in the results obtained from one single sample may be due to poor quality of the measurement method, inappropriate calibration, or improper use of the measurement method by the laboratory. Materials and methods: To evaluate the performance of CREATININE measurement methods, five commonly used kits in Iran, i. e. Pars Azmon, Pishtaz Teb, Audit, Man and Bionik, were evaluated for uncertainty, detection capabilities, linearity and comparison of results. The results were statistically analyzed by using the coefficient of variation, T-test and linear regression and clinically evaluated based on the allowable total error. Results: The imprecision and detection capabilities of the kits were acceptable, but linearity results were not acceptable according to measurement range provided by the manufacturers, exept for Audit and Bionik kits. In addition, statistically in all cases and clinically in most cases, there was a significant difference between the results of each kit with the total mean results as the target level. Conclusion: According to the results of this study, which have been performed in Iran for the first time, it is necessary to replace the JAFFE'S METHOD CREATININE measurements with the enzymatic methods. In addition, the homogenization and standardization of these methods in comparison to a reference method is necessary.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Atabi, Fereshteh, & MOHAMMADI, REZA. (2018). EVALUATION OF THE PERFORMANCE OF COMMON KITS FOR THE MEASUREMENT OF CREATININE IN SERUM AND URINE: ARE THE RESULTS OF THESE METHODS SUITABLE FOR CLINICAL USE?. MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY, 28(2 ), 162-169. SID. https://sid.ir/paper/98607/en

    Vancouver: Copy

    Atabi Fereshteh, MOHAMMADI REZA. EVALUATION OF THE PERFORMANCE OF COMMON KITS FOR THE MEASUREMENT OF CREATININE IN SERUM AND URINE: ARE THE RESULTS OF THESE METHODS SUITABLE FOR CLINICAL USE?. MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY[Internet]. 2018;28(2 ):162-169. Available from: https://sid.ir/paper/98607/en

    IEEE: Copy

    Fereshteh Atabi, and REZA MOHAMMADI, “EVALUATION OF THE PERFORMANCE OF COMMON KITS FOR THE MEASUREMENT OF CREATININE IN SERUM AND URINE: ARE THE RESULTS OF THESE METHODS SUITABLE FOR CLINICAL USE?,” MEDICAL SCIENCES JOURNAL OF ISLAMIC AZAD UNIVERSITY, vol. 28, no. 2 , pp. 162–169, 2018, [Online]. Available: https://sid.ir/paper/98607/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button