مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,167
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

192
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION OF THE TOTAL ANALYTICAL ERROR IN THE FLAME PHOTOMETRY METHOD

Pages

  65-68

Abstract

 Background and Objectives: For TOTAL ANALYTICAL ERROR, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A TOTAL ANALYTICAL ERROR goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. Materials and Methods: Fifty vials of SODIUM and POTASSIUM standards (Sandos Company) were chosen. Then, the concentration of SODIUM and POTASSIUM in these standards were daily measured using FLAME PHOTOMETRY for 50 days at biochemistry laboratory (Ghaem hospital, Mashhad). Thereafter, the mean, standard deviation, random and systematic analytical errors, and TOTAL ANALYTICAL ERROR from these values were calculated. Results: The systematic and random analytical errors for standard specimens using FLAME PHOTOMETRY method for SODIUM and POTASSIUM are  me (Na)=0.36, me (k)=0.012, se (Na)=0.69 and se (k)=0.11 respectively. Meanwhile, the TOTAL ANALYTICAL ERROR of FLAME PHOTOMETRY for measurement of SODIUM and POTASSIUM was 1.74 mM/l and 0.232 mM/l respectively. Conclusion: In this study, it was found out that FLAME PHOTOMETRY system has good precision and accuracy and its TOTAL ANALYTICAL ERROR for measuring of SODIUM and POTASSIUM are within the acceptable range.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    AYAT ELAHI, HOSSEIN, KIANOUSH, T., & KHAJEH DALOUEI, M.. (2006). EVALUATION OF THE TOTAL ANALYTICAL ERROR IN THE FLAME PHOTOMETRY METHOD. IRANIAN JOURNAL OF PATHOLOGY (IJP), 1(2), 65-68. SID. https://sid.ir/paper/123823/en

    Vancouver: Copy

    AYAT ELAHI HOSSEIN, KIANOUSH T., KHAJEH DALOUEI M.. EVALUATION OF THE TOTAL ANALYTICAL ERROR IN THE FLAME PHOTOMETRY METHOD. IRANIAN JOURNAL OF PATHOLOGY (IJP)[Internet]. 2006;1(2):65-68. Available from: https://sid.ir/paper/123823/en

    IEEE: Copy

    HOSSEIN AYAT ELAHI, T. KIANOUSH, and M. KHAJEH DALOUEI, “EVALUATION OF THE TOTAL ANALYTICAL ERROR IN THE FLAME PHOTOMETRY METHOD,” IRANIAN JOURNAL OF PATHOLOGY (IJP), vol. 1, no. 2, pp. 65–68, 2006, [Online]. Available: https://sid.ir/paper/123823/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button