مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

727
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

STRESS DISTRIBUTION IN BAR OF OVERDENTURE SUPPORTED IMPLANTS BY THREEDIMENSIONAL FINITE ELEMENTS ANALYSIS

Pages

  332-339

Abstract

 Introduction: Mean bar failure in OVERDENTURE-supported implant has been reported to be 3.97 percent, even this low failure rate is unacceptable for patients because of its cost compared with complete denture. The aim of this study was to assess stress distribution in different points of the bar of OVERDENTURE-supported implants by finite elements analysis.Materials and Methods: In this descriptive study, stress distribution on the bar of mandibular OVERDENTURE was evaluated by the finite elements analysis (FEA). Implants in two canine areas were connected to each other by one bar at the distance of 2 mm from the lining tissue of the edentulous ridge. Then the vertical force applied to the left first molar increased gradually from 0.5 to 50 N and stress distributions were recorded at different points of the bar.Results: By increasing the force up to 6.06 N, stress was uniformly distributed over the bar, but with greater force stress was focused on the border of the middle third and the force application third. This pattern of stress distribution continued parallel with an increase in the force.Conclusion: Failure is higher at the border area between the middle third of the bar and the third near the applied force due to maximum stress, therefore, reinforcement of the bar at this area is suggested.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    GHASEMI, EHSAN, SADEGHI, MOHAMMAD ALI, DAKHIL ALIAN, MANSOUR, & RISMANCHIAN, MANSOUR. (2011). STRESS DISTRIBUTION IN BAR OF OVERDENTURE SUPPORTED IMPLANTS BY THREEDIMENSIONAL FINITE ELEMENTS ANALYSIS. JOURNAL OF ISFAHAN DENTAL SCHOOL, 6(4), 332-339. SID. https://sid.ir/paper/126122/en

    Vancouver: Copy

    GHASEMI EHSAN, SADEGHI MOHAMMAD ALI, DAKHIL ALIAN MANSOUR, RISMANCHIAN MANSOUR. STRESS DISTRIBUTION IN BAR OF OVERDENTURE SUPPORTED IMPLANTS BY THREEDIMENSIONAL FINITE ELEMENTS ANALYSIS. JOURNAL OF ISFAHAN DENTAL SCHOOL[Internet]. 2011;6(4):332-339. Available from: https://sid.ir/paper/126122/en

    IEEE: Copy

    EHSAN GHASEMI, MOHAMMAD ALI SADEGHI, MANSOUR DAKHIL ALIAN, and MANSOUR RISMANCHIAN, “STRESS DISTRIBUTION IN BAR OF OVERDENTURE SUPPORTED IMPLANTS BY THREEDIMENSIONAL FINITE ELEMENTS ANALYSIS,” JOURNAL OF ISFAHAN DENTAL SCHOOL, vol. 6, no. 4, pp. 332–339, 2011, [Online]. Available: https://sid.ir/paper/126122/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button