مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,050
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETERMINATION OF THE COLLIMATOR SCATTER FACTOR BY THE CORRECTION STERLING FORMULA FOR ASYMMETRICAL FIELD RADIATION THERAPY WITH MEGAVOLTAGE PHOTON BEAM

Author(s)

 TAHMASEBI BIRGANI MOHAMMAD JAVAD | CHEGENI NAHID | BEHROOZ MOHAMMAD ALI | ZABIHZADEH MANSOUR | HABIBI AMENE | Issue Writer Certificate 

Pages

  45-51

Abstract

 Background and Objective: The output factor is an important factor in calculating the dose in the treatment of cancer patients with Megavoltage photon beams. Since in the most cases, the treatment field is asymmetric, therefore the calculation of this factor is very important. Subjects and Methods: Measurements were done for Siemens Primus Plus accelerator, Golestan Hospital using Farmer ionization chamber 6cc. The output factors was measured for the symmetric fields and calibration curves were plotted for COLLIMATOR SCATTER FACTOR. For each symmetric square field, many asymmetrical fields were defined. Using analysis and comparison with measured values for Siemens Linac, a tuning parameter was calculated for each symmetric square field. Then, the tuning parameter was applied to calculate COLLIMATOR SCATTER FACTOR for the corresponding ASYMMETRIC FIELD. Finally the calculation results were compared with experimental values.Results: The tuning parameter for the two symmetric fields 30×30 and 25×25 were 0.452±0.001 and 0.481±0.001 respectively. Taking into account this tuning parameter for ASYMMETRIC FIELDs, the maximum percentage difference between calculated and measured results, was 0.7%.Conclusions: Results indicate a reduction in the asymmetric COLLIMATOR SCATTER FACTOR relative to the symmetrical field. In addition, with increase in distance from center of symmetry, it becomes more significant decline. Also according to the calibration curve, the equivalent square field side for every ASYMMETRIC FIELD can be obtained.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAHMASEBI BIRGANI, MOHAMMAD JAVAD, CHEGENI, NAHID, BEHROOZ, MOHAMMAD ALI, ZABIHZADEH, MANSOUR, & HABIBI, AMENE. (2017). DETERMINATION OF THE COLLIMATOR SCATTER FACTOR BY THE CORRECTION STERLING FORMULA FOR ASYMMETRICAL FIELD RADIATION THERAPY WITH MEGAVOLTAGE PHOTON BEAM. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, 16(1 ), 45-51. SID. https://sid.ir/paper/12957/en

    Vancouver: Copy

    TAHMASEBI BIRGANI MOHAMMAD JAVAD, CHEGENI NAHID, BEHROOZ MOHAMMAD ALI, ZABIHZADEH MANSOUR, HABIBI AMENE. DETERMINATION OF THE COLLIMATOR SCATTER FACTOR BY THE CORRECTION STERLING FORMULA FOR ASYMMETRICAL FIELD RADIATION THERAPY WITH MEGAVOLTAGE PHOTON BEAM. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL[Internet]. 2017;16(1 ):45-51. Available from: https://sid.ir/paper/12957/en

    IEEE: Copy

    MOHAMMAD JAVAD TAHMASEBI BIRGANI, NAHID CHEGENI, MOHAMMAD ALI BEHROOZ, MANSOUR ZABIHZADEH, and AMENE HABIBI, “DETERMINATION OF THE COLLIMATOR SCATTER FACTOR BY THE CORRECTION STERLING FORMULA FOR ASYMMETRICAL FIELD RADIATION THERAPY WITH MEGAVOLTAGE PHOTON BEAM,” JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, vol. 16, no. 1 , pp. 45–51, 2017, [Online]. Available: https://sid.ir/paper/12957/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    File Not Exists.
    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button