مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

715
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF THE EFFECT OF THREE LED LIGHT MODES AND CONVENTIONAL QTH CURING LIGHT ON SHEAR BOND STRENGTH OF COMPOSITE TO DENTIN

Pages

  136-141

Abstract

 Objective: SHEAR BOND STRENGTH is an important property inherent to the durability of tooth-colored restorative materials namely composite resins. It has been years that halogen light sources have been used for polymerization of composite resins. In recent years Light Emitting Diodes (LED) have been introduced for this purpose. With respect to their longer bulb life, needless of a filter and no heat production, the demand for their use has increased. This study aimed to compare three different LED curing-lights with conventional Quartz Tungsten Halogen (QTH) lights to assess their effects on SHEAR BOND STRENGTH of composite to dentin.Methods: In this laboratory study, 60sound caries-free premolar teeth, after disinfection with sodium hypochlorite and cleaning with a scaler, were divided into four groups of 15. After the specimens had their dentin surface exposed with a metal disc, the composite restoration was done. The restorations in each group were done using Single Bond bonding agent and cured with the QTH LIGHT CURING UNITs and three different LED curing devices. Next, the strength of each bond was measured with an Instron Machine. The results were analyzed with one-way ANOV A and Tukey's test.Results: Analysis of the data with one-way ANOVA revealed statistically significant differences between the groups (P<0.05). The greatest bond strength related to the LED light in ramp mode with 114.68 Newtons (N) or 22.94 megapascals (MPa).The lowest related to the pulsed-LED with a mean of 70.35 N (l4.70 MPa). In pair wise comparison of the 4 groups with Tukey's test, all groups with the exception of QTH with a mean of 99 N(l9.80MPa) and the conventional LED with a mean of 86.78N (l7.35 MPa), had a significant difference (P<0.05).Conclusion: Our study showed that the use of LED light in ramp mode had better results compared to the QTH light source (control group) (P=0.38). Conventional LED light was comparable to the QTH light as well (P=0.169).

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KAVIANI, AZITA, DABAGHI TABRIZ, FATEMEH, KHALAJ, KAVEH, & NESHATI, AMAR. (2013). COMPARISON OF THE EFFECT OF THREE LED LIGHT MODES AND CONVENTIONAL QTH CURING LIGHT ON SHEAR BOND STRENGTH OF COMPOSITE TO DENTIN. JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE, 31(3 (99)), 136-141. SID. https://sid.ir/paper/21719/en

    Vancouver: Copy

    KAVIANI AZITA, DABAGHI TABRIZ FATEMEH, KHALAJ KAVEH, NESHATI AMAR. COMPARISON OF THE EFFECT OF THREE LED LIGHT MODES AND CONVENTIONAL QTH CURING LIGHT ON SHEAR BOND STRENGTH OF COMPOSITE TO DENTIN. JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE[Internet]. 2013;31(3 (99)):136-141. Available from: https://sid.ir/paper/21719/en

    IEEE: Copy

    AZITA KAVIANI, FATEMEH DABAGHI TABRIZ, KAVEH KHALAJ, and AMAR NESHATI, “COMPARISON OF THE EFFECT OF THREE LED LIGHT MODES AND CONVENTIONAL QTH CURING LIGHT ON SHEAR BOND STRENGTH OF COMPOSITE TO DENTIN,” JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE, vol. 31, no. 3 (99), pp. 136–141, 2013, [Online]. Available: https://sid.ir/paper/21719/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button