مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

874
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECT OF PULP TESTER PROBE PLACEMENT SITE ON THE RESPONSE OF MAXILLARY ANTERIOR TEETH

Pages

  196-201

Abstract

 Background and Aims: Electric pulp testing is used for diagnosis of the pulp status. This test is technique sensitive and hence may elicit positive or negative false response in case of inaccurate use. The optimal site for placement of the PROBE tip has not been determined. The aim of this study was to evaluate the effect of PULP TESTER PROBE placement site on the response of maxillary teeth.Materials and Methods: A total of 378 teeth (126 central incisors, 126 lateral incisors and 126 canines) in 67 voluntary 20-35 year-old patients were selected. Three sites on each tooth (incisal edge, labial and lingual surfaces) were tested with an electrical PULP TESTER and responses were recorded. Data were analyzed by Repeated Measure ANOVA test.Results: The central incisor teeth showed significantly lower sensation threshold than lateral incisor and canine teeth (P<0.001). The incisal edge of tooth were significantly more sensitive compared to labial and lingual surfaces (P=0.008).Conclusion: This study showed that the optimum site for placement of PULP TESTER PROBE was incisal edge.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MODARESI, JALIL, HESHMAT MOHAJER, AMIR REZA, AGHILI, HOSSEIN, KHORSHIDI, MORTEZA, ROSTAMI CHAVOSHLO, FARAMARZ, & MAHABADI, AMIR MOHAMAD. (2012). EFFECT OF PULP TESTER PROBE PLACEMENT SITE ON THE RESPONSE OF MAXILLARY ANTERIOR TEETH. JOURNAL OF DENTAL MEDICINE, 25(3 (72)), 196-201. SID. https://sid.ir/paper/25709/en

    Vancouver: Copy

    MODARESI JALIL, HESHMAT MOHAJER AMIR REZA, AGHILI HOSSEIN, KHORSHIDI MORTEZA, ROSTAMI CHAVOSHLO FARAMARZ, MAHABADI AMIR MOHAMAD. EFFECT OF PULP TESTER PROBE PLACEMENT SITE ON THE RESPONSE OF MAXILLARY ANTERIOR TEETH. JOURNAL OF DENTAL MEDICINE[Internet]. 2012;25(3 (72)):196-201. Available from: https://sid.ir/paper/25709/en

    IEEE: Copy

    JALIL MODARESI, AMIR REZA HESHMAT MOHAJER, HOSSEIN AGHILI, MORTEZA KHORSHIDI, FARAMARZ ROSTAMI CHAVOSHLO, and AMIR MOHAMAD MAHABADI, “EFFECT OF PULP TESTER PROBE PLACEMENT SITE ON THE RESPONSE OF MAXILLARY ANTERIOR TEETH,” JOURNAL OF DENTAL MEDICINE, vol. 25, no. 3 (72), pp. 196–201, 2012, [Online]. Available: https://sid.ir/paper/25709/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button