مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

779
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

TUMOR DOSE ERROR ANALYSIS FOR MEGAVOLTAGE OPEN AND BLOCKED FIELDS USING MEASURED SCATTER CORRECTION FACTORS

Pages

  157-161

Abstract

 Introduction. The most important goal in radiation therapy is treating the tumor while protecting the surrounding healthy tissue. To achieve this goal the difference between prescribed and deliveredtumor dose has to be less than±2 percent. This study evaluated the necessity of using output factors for changing output of a reference field to the output of other field sizes.Methods. Scp was measured in water and Se in a narrow cylindrical phantom built in this research for cobalt and 12 MV beams. The separation of Scp to Sc and Sp parts for blocked fields was evaluated by comparing the measured and calculated Scp values for blocked fields. Results. Results of this study indicates that if output factors are not used for a 12 MV beam the difference between delivered and prescribed tumor dose is from 13 percent (in largest field) to – 6 percent (in smallest field) ( difference was 8 percent for cobalt beam). The 'method of separating Scp to Se and Sp was verified (maximum difference from measured values was 1.3 percent).Discussion. In the method of using phantom field size for selecting Scp, tumor dose was more than prescribed dose from 2.4 percent (for a 27 percent block) to 7.8 percent (for a 90 percent block) for a 12 MV beam (the error increased by block size and proximity of block to the center).

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHOKRANI, P., & MONADI, SH.. (2000). TUMOR DOSE ERROR ANALYSIS FOR MEGAVOLTAGE OPEN AND BLOCKED FIELDS USING MEASURED SCATTER CORRECTION FACTORS. JOURNAL OF RESEARCH IN MEDICAL SCIENCES (JRMS), 5(2), 157-161. SID. https://sid.ir/paper/26464/en

    Vancouver: Copy

    SHOKRANI P., MONADI SH.. TUMOR DOSE ERROR ANALYSIS FOR MEGAVOLTAGE OPEN AND BLOCKED FIELDS USING MEASURED SCATTER CORRECTION FACTORS. JOURNAL OF RESEARCH IN MEDICAL SCIENCES (JRMS)[Internet]. 2000;5(2):157-161. Available from: https://sid.ir/paper/26464/en

    IEEE: Copy

    P. SHOKRANI, and SH. MONADI, “TUMOR DOSE ERROR ANALYSIS FOR MEGAVOLTAGE OPEN AND BLOCKED FIELDS USING MEASURED SCATTER CORRECTION FACTORS,” JOURNAL OF RESEARCH IN MEDICAL SCIENCES (JRMS), vol. 5, no. 2, pp. 157–161, 2000, [Online]. Available: https://sid.ir/paper/26464/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button