مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,136
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CORRELATION BETWEEN BLOOD GLUCOSE MEASURED USING GLUCOMETERS AND STANDARD LABORATORY METHODS

Pages

  277-283

Abstract

 Introduction: DIABETES MELLITUS (DM) is the most common chronic and non-communicable disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of DM is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available GLUCOMETERs for detection of blood glucose compared with STANDARD LABORATORY METHODs.Material and Methods: In this study, we compared of CAPILLARY BLOOD GLUCOSE levels of 402 patients as determined by test strips (GLUCOMETER) with VENOUS BLOOD GLUCOSE LEVELS measurements by the enzymatic method (the standard laboratory kit). Results: Of the 402 patients studied, there were 230 (57.2%) males and 172 (42.8%) females; 65 (16.2%) had past history of DM. Their mean age was 40.2 ± 14.9 years (range 3-70), mean BMI was 24.4±3.2 Kg/m2 and mean HCT was 45.4±4.1 percent. The mean blood glucose measurements reported using the Glucomen GLUCOMETER, the Prestic GLUCOMETER and the STANDARD LABORATORY METHOD were 128.0±45.2mg/dl, 127.4±45.9 mg/dL and 125.3±43.2 mg/dL, respectively with increase of HCT (polycytemia); sensivity of devices for detection of hyperglycemia (BS³126 mg/dl) was increased but specificity was decreased (64.7%).Results obtained using the 2 devices had no differences with the standard method levels.Conclusion: Good correlation was observed between the GLUCOMETER and the standard enzymatic method of blood glucose measurements, advocating usage of GLUCOMETERs at home environments.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KALATEH JARI, M., SOHRABI, MOHAMMAD BAGHER, KHOSRAVI, AHMAD, & ZOU ALFAGHARI, P.. (2008). CORRELATION BETWEEN BLOOD GLUCOSE MEASURED USING GLUCOMETERS AND STANDARD LABORATORY METHODS. IRANIAN JOURNAL OF ENDOCRINOLOGY AND METABOLISM (IJEM), 10(3 (SN 39)), 277-283. SID. https://sid.ir/paper/27423/en

    Vancouver: Copy

    KALATEH JARI M., SOHRABI MOHAMMAD BAGHER, KHOSRAVI AHMAD, ZOU ALFAGHARI P.. CORRELATION BETWEEN BLOOD GLUCOSE MEASURED USING GLUCOMETERS AND STANDARD LABORATORY METHODS. IRANIAN JOURNAL OF ENDOCRINOLOGY AND METABOLISM (IJEM)[Internet]. 2008;10(3 (SN 39)):277-283. Available from: https://sid.ir/paper/27423/en

    IEEE: Copy

    M. KALATEH JARI, MOHAMMAD BAGHER SOHRABI, AHMAD KHOSRAVI, and P. ZOU ALFAGHARI, “CORRELATION BETWEEN BLOOD GLUCOSE MEASURED USING GLUCOMETERS AND STANDARD LABORATORY METHODS,” IRANIAN JOURNAL OF ENDOCRINOLOGY AND METABOLISM (IJEM), vol. 10, no. 3 (SN 39), pp. 277–283, 2008, [Online]. Available: https://sid.ir/paper/27423/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button