Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

335
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

118
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS

Pages

  188-197

Abstract

 Performing cochlear implantation in patients with INNER EAR MALFORMATION has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC) in a patient with RILEY-DAY SYNDROME and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondinis dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity), the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    KHALESSI, M.H., MOTESADI ZARANDI, MASOUD, BORGHEEI, P., & ABDI, S.A.. (2004). COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS. ACTA MEDICA IRANICA, 42(3), 188-197. SID. https://sid.ir/paper/277603/en

    Vancouver: Copy

    KHALESSI M.H., MOTESADI ZARANDI MASOUD, BORGHEEI P., ABDI S.A.. COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS. ACTA MEDICA IRANICA[Internet]. 2004;42(3):188-197. Available from: https://sid.ir/paper/277603/en

    IEEE: Copy

    M.H. KHALESSI, MASOUD MOTESADI ZARANDI, P. BORGHEEI, and S.A. ABDI, “COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS,” ACTA MEDICA IRANICA, vol. 42, no. 3, pp. 188–197, 2004, [Online]. Available: https://sid.ir/paper/277603/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top