مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

234
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

76
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARING OF IMAGE QUALITY OF AXIAL AND CORONAL CT SCAN OF TEMPORAL BONE

Pages

  84-86

Abstract

 CT IMAGE QUALITY has been affected by many factors such as KVP, ma, exposure time, alogorithm and section thickness. Gantry tilt has the main role in visualization of the TEMPORAL BONE anatomic structures. In this study, we tried to optimize these factors to determine the best gantry tilt. This study was performed on the human skull phantom and then extended to 15 patients. The phantom was made by inserting a normal human dry skull into a water- filled radiolucent cylindrical container. A lateral scout view was obtained and the OMBL (orbitomeatal baseline) was used as the anatomical landmark.The phantom was scanned in 9, 15 , 30 , 45, 60 , 75, 90,105, 120 degree in relation to OMBL and 24 important anatomical structures were evaluated in each. Kilovoltage of 80, 120, 140 millimeters of 40, 70, 100, 120, 140, 170, 200, 240, exposue time of 2, 2, 4 second , algorithm of smooth, soft, standard, detail, bone adge and section thickness of 1.5, 3,5 millimeter were studied separately. In general, most of the anatomical structures are well demonstrated in 0 or 30 degrees of axial scans and 90 or 105 degrees in coronal scans. The best imaging techniques in Kv=140, Ma=100, S=2 seconds, algorithm of edge or bone, section thickness of 1.5 millimeter for small structures and 3 millineters for greater ones.The best 3-D image is provided by 3 millimeter slice thickness without overlapping but they couldn’t assist in diagnosis of our patient’s diseases. In indirect sagital reformatted images, the greater anatomical structures such as vestibule and cochlea are also shown, but they are recommended due to the slight degradation of the images and some loss of resolution.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GHAANATI, H., SHARAFI, A.A., & SOROUSH, H.. (2000). COMPARING OF IMAGE QUALITY OF AXIAL AND CORONAL CT SCAN OF TEMPORAL BONE. ACTA MEDICA IRANICA, 38(2), 84-86. SID. https://sid.ir/paper/277740/en

    Vancouver: Copy

    GHAANATI H., SHARAFI A.A., SOROUSH H.. COMPARING OF IMAGE QUALITY OF AXIAL AND CORONAL CT SCAN OF TEMPORAL BONE. ACTA MEDICA IRANICA[Internet]. 2000;38(2):84-86. Available from: https://sid.ir/paper/277740/en

    IEEE: Copy

    H. GHAANATI, A.A. SHARAFI, and H. SOROUSH, “COMPARING OF IMAGE QUALITY OF AXIAL AND CORONAL CT SCAN OF TEMPORAL BONE,” ACTA MEDICA IRANICA, vol. 38, no. 2, pp. 84–86, 2000, [Online]. Available: https://sid.ir/paper/277740/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button