مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

225
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

121
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Diffusion-Weighted Imaging and Proton Magnetic Resonance Spectroscopy Findings in Osteosarcoma Versus Normal Muscle

Pages

  0-0

Abstract

 Objectives: The goal of our studywasto assess diffusion-weighted(DW)imagingandproton magnetic resonance (MR) spectroscopy findings in Osteosarcoma versus Normal Muscle at 3 Tesla (3 T) MR system. Patients and Methods: Nineteen patients highly suspicious for Osteosarcoma and 12 normal young healthy adults were enrolled in this study. Two patients were excluded from the study due to incompatible histopathologic results. DW imaging and multivoxel Proton MR Spectroscopy at 3 T were performed for all participants. Surgical biopsy and histopathological examination were done for every patient after imaging. SPSS 20 was used for statistical analysis. Results: The minimum apparent diffusion coefficient (ADC) value of Osteosarcoma (0. 88 0. 28) in this study confirms the significant restriction of this tumor against the dark background of Normal Muscle in high b-value images. Fourteen (82%) of the available 17 patients had ADC values 1 10-3 mm2/s. The maximum choline/creatine (Cho/Cr) ratio of Osteosarcoma (1. 94 1. 12) was statistically higher than the Normal Muscle (1. 34 0. 11). Receiver operating curve (ROC) analysis (the area under the curve = 0. 7) indicated a maximum Cho/Cr ratio of 1. 37 as the cut point between the Normal Muscle and Osteosarcoma, with a sensitivity, specificity and accuracy of 58. 8%, 83. 3%, and 69%, respectively. All patients with Cho/Cr ratios more than the cut point had ADC values  1  10-3 mm2/s and all patients with ADC values higher than 1 10-3 mm2/s had Cho/Cr ratios 1. 37. Conclusion: It was concluded that DW imaging and Proton MR Spectroscopy are two effective noninvasive techniques in the evaluation of Osteosarcoma.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MALEK, MAHROOZ, KAZEMI, MOHAMAD ALI, SABERI, SADEGH, HASHEMI, HASSAN, & MORADI, BEHNAZ. (2017). Diffusion-Weighted Imaging and Proton Magnetic Resonance Spectroscopy Findings in Osteosarcoma Versus Normal Muscle. IRANIAN JOURNAL OF RADIOLOGY, 14(4), 0-0. SID. https://sid.ir/paper/284666/en

    Vancouver: Copy

    MALEK MAHROOZ, KAZEMI MOHAMAD ALI, SABERI SADEGH, HASHEMI HASSAN, MORADI BEHNAZ. Diffusion-Weighted Imaging and Proton Magnetic Resonance Spectroscopy Findings in Osteosarcoma Versus Normal Muscle. IRANIAN JOURNAL OF RADIOLOGY[Internet]. 2017;14(4):0-0. Available from: https://sid.ir/paper/284666/en

    IEEE: Copy

    MAHROOZ MALEK, MOHAMAD ALI KAZEMI, SADEGH SABERI, HASSAN HASHEMI, and BEHNAZ MORADI, “Diffusion-Weighted Imaging and Proton Magnetic Resonance Spectroscopy Findings in Osteosarcoma Versus Normal Muscle,” IRANIAN JOURNAL OF RADIOLOGY, vol. 14, no. 4, pp. 0–0, 2017, [Online]. Available: https://sid.ir/paper/284666/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button