مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

165
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

97
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination

Pages

  0-0

Abstract

 Background: Using a low volume of contrast medium and tube voltage may enhance the opacification of pulmonary arteries and thrombus detection without decreasing the image quality. In addition, this protocol can also ensure that exposure of the patient to the contrast medium and radiation dose may be significantly reduced. Objectives: The purpose of this study was to investigate the efficiency of Low Tube Voltage and low dose iodine-based contrast mediumin computed tomography pulmonary angiography (CTPA) and optimize its use in the diagnosis of Pulmonary Thromboembolism (PTE). Patients and Methods: We included a total of 100 patients undergoing CTPA with an initial diagnosis of PTE into two groups: group A (n = 50) was given a contrast medium (CM) dose of 0. 5 mL/kg at 80 kV while group B (n = 50) was given a CM dose of 1 mL/kg at 100 kV. Bolus tracking technique was used. Attenuation values were measured from the center of different pulmonary arterial segments. Values over 350 Hounsfield unit (HU) were accepted as significant. Imagequalities of allpulmonary arterial segments were sufficient for diagnosis. The mean and effective doses of radiation received by patients in the two groups were compared. Results: PTE was detected in twenty-one patients (21%) in both groups. Total mean attenuation values for pulmonary arteries were significantly higher in group A than in group B (532. 7 243HUvs. 380. 6 232HUrespectively, P < 0. 001). Total dose length product (DLP) (76. 5 17. 3 mGy. cm vs. 162. 1 31. 3 mGy. cm, P < 0. 001) and effective dose values (1. 2 0. 2 mSv vs. 2. 4 0. 2 mSv, P < 0. 001) were significantly lower in group A compared to group B. Conclusion: CTPAmaybeobtained usinganimagingprotocol withlowkVandreducedvolumeof contrastmediumin the diagnosis of PTE.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    KARA, MUSTAFA, Kayan, Mustafa, Cetinkaya, Gursel, Turkoglu, Sefa, & Kayan, Fatma. (2018). Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination. IRANIAN JOURNAL OF RADIOLOGY, 15(3), 0-0. SID. https://sid.ir/paper/284838/en

    Vancouver: Copy

    KARA MUSTAFA, Kayan Mustafa, Cetinkaya Gursel, Turkoglu Sefa, Kayan Fatma. Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination. IRANIAN JOURNAL OF RADIOLOGY[Internet]. 2018;15(3):0-0. Available from: https://sid.ir/paper/284838/en

    IEEE: Copy

    MUSTAFA KARA, Mustafa Kayan, Gursel Cetinkaya, Sefa Turkoglu, and Fatma Kayan, “Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination,” IRANIAN JOURNAL OF RADIOLOGY, vol. 15, no. 3, pp. 0–0, 2018, [Online]. Available: https://sid.ir/paper/284838/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button