مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

313
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

146
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DEVELOPMENT OF A SENSITIVE SPECTROFLUOROMETRIC-MULTIVARIATE CALIBRATION METHOD FOR ENZYME KINETIC OF ALDEHYDE OXIDASE

Pages

  169-177

Abstract

 Attempts to obtain experimental values for the kinetic parameters of PHENANTHRIDINE oxidation by guinea pig or rabbit liver ALDEHYDE OXIDASE using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of ALDEHYDE OXIDASE activity, using PHENANTHRIDINE as the substrate, has been developed and validated. PHENANTHRIDINE and phenanthridinone binary mixtures were prepared in a dynamic linear range of 0.025-1 mM and the emission flourimetric spectra of the solutions recorded at the excitation and emission wavelengths of 236 and 320-450 nm, respectively. The optimized calibration model of PARTIAL LEAST SQUAREs (PLS) method was applied for the simultaneous determination of the concentration of each chemical in the prediction set. The limits of detection for PHENANTHRIDINE and phenanthridinone were found to be 2.13 ± 0.33 and 3.41 ± 0.34 nM (mean ±  SD, n = 5), respectively. This method was then used for kinetic study of PHENANTHRIDINE oxidation using guinea pig and rat hepatic ALDEHYDE OXIDASE. The results were compared with those obtained from a univariate spectroscopic method. Using this new spectrofluorimetric-multivariate calibration method, the Km value for the oxidation of PHENANTHRIDINE with guinea pig and rat liver ALDEHYDE OXIDASE were obtained as 0.83 ±  0.08 and 2.20 ±  0.40, mM (mean ±  SD, n = 3), respectively.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SOROUR ALDIN, M.H., FOULADI, E., NASERI, A.A.H., & RASHIDI, M.R.. (2009). DEVELOPMENT OF A SENSITIVE SPECTROFLUOROMETRIC-MULTIVARIATE CALIBRATION METHOD FOR ENZYME KINETIC OF ALDEHYDE OXIDASE. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH (IJPR), 8(3), 169-177. SID. https://sid.ir/paper/287732/en

    Vancouver: Copy

    SOROUR ALDIN M.H., FOULADI E., NASERI A.A.H., RASHIDI M.R.. DEVELOPMENT OF A SENSITIVE SPECTROFLUOROMETRIC-MULTIVARIATE CALIBRATION METHOD FOR ENZYME KINETIC OF ALDEHYDE OXIDASE. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH (IJPR)[Internet]. 2009;8(3):169-177. Available from: https://sid.ir/paper/287732/en

    IEEE: Copy

    M.H. SOROUR ALDIN, E. FOULADI, A.A.H. NASERI, and M.R. RASHIDI, “DEVELOPMENT OF A SENSITIVE SPECTROFLUOROMETRIC-MULTIVARIATE CALIBRATION METHOD FOR ENZYME KINETIC OF ALDEHYDE OXIDASE,” IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH (IJPR), vol. 8, no. 3, pp. 169–177, 2009, [Online]. Available: https://sid.ir/paper/287732/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button