Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

345
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

119
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

MITOMYCIN-C TRABECULECTOMY VERSUS AHMED GLAUCOMA IMPLANT IN PEDIATRIC APHAKIC GLAUCOMA

Pages

  28-34

Keywords

Not Registered.

Abstract

 Purpose: To compare the outcomes and complications of mitomycin-C trabeculectomy (MMC-T) versus the Ahmed glaucoma implant (AGI) for treatment of pediatric aphakic glaucoma.Methods: In a randomized clinical trial, 30 eyes of 28 children <16 years of age who had undergone anterior lensectomy-vitrectomy for congenital cataract were assigned to MMC-T (15 eyes of 13 children) or AGI (15 eyes of 15 children). Surgical success was classified as complete (IOP 6-21 mmHg without any antiglaucoma medication) and partial (IOP 6-21 mmHg with £2 topical antiglaucoma agents) in the absence of any sight-threatening complication or need for further glaucoma surgery, stable cup/disc ratios and visual loss £2 Snellen lines. Overall success was defined as the sum of complete and partial success.Results: Mean patient age was 9.1±4.1 and 10.9±5.1 years in the MMC-T and AGI groups, respectively (P=0.29). After a mean follow up of 14.8±11 and 13.1±9.7 months; complete, partial and overall success rates were 33.3%, 40% and 73.3% in the MMC-T vs 20%, 66.7% and 86.7% in the AGI groups, respectively (P= 0.361). Complication and failure rates were 40% and 26.7% in the MMC-T group vs 26.7% and 13.3% in the AGI group, respectively (P= 0.439).Conclusion: MMC-T and AGI seem to be comparable in terms of success and complications as the initial surgical procedure in pediatric aphakic glaucoma. Choice of either technique depends on surgeon’s experience and conjunctival quality and mobility.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    PAKRAVAN, MOHAMMAD, NIKKHAH, H., BARADARAN RAFIEI, ALI REZA, & YAZDANI, SHAHIN. (2007). MITOMYCIN-C TRABECULECTOMY VERSUS AHMED GLAUCOMA IMPLANT IN PEDIATRIC APHAKIC GLAUCOMA. JOURNAL OF OPHTHALMIC AND VISION RESEARCH, 2(1), 28-34. SID. https://sid.ir/paper/311330/en

    Vancouver: Copy

    PAKRAVAN MOHAMMAD, NIKKHAH H., BARADARAN RAFIEI ALI REZA, YAZDANI SHAHIN. MITOMYCIN-C TRABECULECTOMY VERSUS AHMED GLAUCOMA IMPLANT IN PEDIATRIC APHAKIC GLAUCOMA. JOURNAL OF OPHTHALMIC AND VISION RESEARCH[Internet]. 2007;2(1):28-34. Available from: https://sid.ir/paper/311330/en

    IEEE: Copy

    MOHAMMAD PAKRAVAN, H. NIKKHAH, ALI REZA BARADARAN RAFIEI, and SHAHIN YAZDANI, “MITOMYCIN-C TRABECULECTOMY VERSUS AHMED GLAUCOMA IMPLANT IN PEDIATRIC APHAKIC GLAUCOMA,” JOURNAL OF OPHTHALMIC AND VISION RESEARCH, vol. 2, no. 1, pp. 28–34, 2007, [Online]. Available: https://sid.ir/paper/311330/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top