DIAGNOSTIC USEFULNESS OF TRANSCUTANEOUS BILIRUBINOMETRY IN VERY PRETERM NEWBORNS

Pages

  262-265

Abstract

 Background: This study was performed to find out whether transcutaneous bilirubinometry could be a valid screening method for hyperbilirubinemia in preterm infants, especially for those who needed mechanical ventilation.Methods: We evaluated 63 preterm Iranian newborns who were managed in the neonatal intensive care unit of Shahidbeheshti University Hospital, Isfahan, Iran from April 2009 to April 2010. Transcutaneous bilirubin (TCB) measurements were obtained using BiliCheck™ shortly before or 10 minutes after taking blood for determination of the plasma bilirubin level in premature newborns, who did not receive PHOTOTHERAPY. We assessed the correlation between the transcutaneous bilirubin and plasma bilirubin level by linear regression analysis. We also analyzed the gestational age, birth weight, postnatal age, sex, and hematocrit, for determination of their effect on transcutaneous bilirubin accuracy.Results: The overall bilirubin concentration ranged from 5.4 to 17 mg/dL and from 4.8 to 17.3 mg/dl for total serum bilirubin (TSB) and transcutaneous bilirubin, respectively. The mean values obtained by transcutaneous bilirubinometry were slightly higher than the total TSB values. The correlation coefficient between TSB and TCB was r=0.82, P<0.001, and this was not influenced by gestational age, postnatal age or hematocrit, which were previously considered to be important. The correlation coefficient between TSB and TCB in mechanically ventilated preterm infants was r=0.75, P<0.001.Conclusion: Plasma bilirubin level can be accurately measured by BiliCheck™ in premature newborns, even in newborns who need mechanical ventilation.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BADIEE, ZOHREH, MOHAMMADIZADEH, MAJID, & SHAMEE, MASIH. (2012). DIAGNOSTIC USEFULNESS OF TRANSCUTANEOUS BILIRUBINOMETRY IN VERY PRETERM NEWBORNS. INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, 3(4), 262-265. SID. https://sid.ir/paper/316000/en

    Vancouver: Copy

    BADIEE ZOHREH, MOHAMMADIZADEH MAJID, SHAMEE MASIH. DIAGNOSTIC USEFULNESS OF TRANSCUTANEOUS BILIRUBINOMETRY IN VERY PRETERM NEWBORNS. INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE[Internet]. 2012;3(4):262-265. Available from: https://sid.ir/paper/316000/en

    IEEE: Copy

    ZOHREH BADIEE, MAJID MOHAMMADIZADEH, and MASIH SHAMEE, “DIAGNOSTIC USEFULNESS OF TRANSCUTANEOUS BILIRUBINOMETRY IN VERY PRETERM NEWBORNS,” INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, vol. 3, no. 4, pp. 262–265, 2012, [Online]. Available: https://sid.ir/paper/316000/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button