EFFICACY OF BIOFILM REMOVAL FROM HEMODIALYSIS PIPING

Pages

  0-0

Abstract

 Background: CENTRAL DIALYSATE FLUID DELIVERY SYSTEMs (CDDS) are used by dialysis centers in Japan, and although these systems are effective at delivering dialysate, they have a complex piping network with numerous sites where contamination can develop. In Japan, cleaning disinfectants have been clinically evaluated based on endotoxin levels and bacterial counts, but there have been no published studies evaluating the BIOFILM removal efficacy of these agents at the electron microscope level.Objectives: In this study, we used electron microscopy to evaluate the effectiveness of various cleaning disinfectants in removing BIOFILMs from hemodialysis piping.Methods: Liquid nitrogen was used to sever a section of dialysis piping on which a BIOFILM had formed during clinical use. Sodium hypochlorite, acetic acid, and peracetic acid were used at stock-solution concentrations as cleaning disinfectants. These disinfectants were tested at room temperature and when heated (80°C). After cleaning and disinfection, BIOFILM removal from the surface of the piping was evaluated using a scanning electron microscope (SEM).Results: Sodium hypochlorite did not show good BIOFILM removal at room temperature or when heated. Acetic acid was more effective at BIOFILM removal when heated than at room temperature. Peracetic acid was highly effective at BIOFILM removal at both room temperature and when heated Conclusions: Cleaning and disinfection using a disinfectant at a high temperature and high concentration effectively removes BIOFILMs from hemodialysis piping. However, long-term exposure to disinfectants may affect the piping material.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ISAKOZAWA, YUTAKA, MIGITA, HEIHACHI, & TAKESAWA, SHINGO. (2016). EFFICACY OF BIOFILM REMOVAL FROM HEMODIALYSIS PIPING. THE JOURNAL OF NEPHRO-UROLOGY MONTHLY, 8(5), 0-0. SID. https://sid.ir/paper/323818/en

    Vancouver: Copy

    ISAKOZAWA YUTAKA, MIGITA HEIHACHI, TAKESAWA SHINGO. EFFICACY OF BIOFILM REMOVAL FROM HEMODIALYSIS PIPING. THE JOURNAL OF NEPHRO-UROLOGY MONTHLY[Internet]. 2016;8(5):0-0. Available from: https://sid.ir/paper/323818/en

    IEEE: Copy

    YUTAKA ISAKOZAWA, HEIHACHI MIGITA, and SHINGO TAKESAWA, “EFFICACY OF BIOFILM REMOVAL FROM HEMODIALYSIS PIPING,” THE JOURNAL OF NEPHRO-UROLOGY MONTHLY, vol. 8, no. 5, pp. 0–0, 2016, [Online]. Available: https://sid.ir/paper/323818/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button