مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

892
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ACCURACY OF SURGEON PERFORMED SONOGRAPHY IN BLUNT ABDOMINAL TRAUMA

Pages

  163-166

Keywords

FOCUSED ASSESSMENT WITH SONOGRAPHY FOR TRAUMA (FAST)Q3

Abstract

 Aims: Focused Assessment with Sonography for Trauma (FAST) is used as a screening tool to detect hemoperitoneum in patients with blunt abdominal injuries in many trauma centers all over the world. However, Iranian trauma centers are unaccustomed to performing it as a routine. The aim of this study was to evaluate the SENSITIVITY and SPECIFICITY of FAST performed by surgeons and to announce its advantages to Iranian surgeons Materials & Methods: Data were collected prospectively in one hundred BLUNT ABDOMINAL TRAUMA patients admitted to Baqyiatallah Hospital from April 2008- April 2009. FAST was used by surgeons or senior surgical residents to detect intra peritoneal fluid and considered positive if such fluid was identified. Data were analyzed using SPSS14.Results: 5 of the 100 patients had proven intra abdominal injuries and 95 had no injuries. FAST result was positive in 7 patients and negative in 93 patients. There were 2 false positive results. The SENSITIVITY and SPECIFICITY of FAST were 100% and 97.8%, respectively. The positive predictive value was 71.4%, the negative predictive value was 100% and the accuracy was 98%.Conclusion: Focused Assessment with Sonography for Trauma which is performed by general surgeons, can detect the presence or absence of intra peritoneal fluid rapidly and accurately. FAST is a potentially valuable tool for better management of trauma patients.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    KHOUSH MOHABAT, H., PANAHI, FARZAD, MEHRVARZ, SH., MOHEBI, HASAN ALI, & BAGHERPOUR JAHROMI, A.. (2010). ACCURACY OF SURGEON PERFORMED SONOGRAPHY IN BLUNT ABDOMINAL TRAUMA. KOWSAR MEDICAL JOURNAL, 15(3), 163-166. SID. https://sid.ir/paper/32745/en

    Vancouver: Copy

    KHOUSH MOHABAT H., PANAHI FARZAD, MEHRVARZ SH., MOHEBI HASAN ALI, BAGHERPOUR JAHROMI A.. ACCURACY OF SURGEON PERFORMED SONOGRAPHY IN BLUNT ABDOMINAL TRAUMA. KOWSAR MEDICAL JOURNAL[Internet]. 2010;15(3):163-166. Available from: https://sid.ir/paper/32745/en

    IEEE: Copy

    H. KHOUSH MOHABAT, FARZAD PANAHI, SH. MEHRVARZ, HASAN ALI MOHEBI, and A. BAGHERPOUR JAHROMI, “ACCURACY OF SURGEON PERFORMED SONOGRAPHY IN BLUNT ABDOMINAL TRAUMA,” KOWSAR MEDICAL JOURNAL, vol. 15, no. 3, pp. 163–166, 2010, [Online]. Available: https://sid.ir/paper/32745/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button