مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,199
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECTS OF LOW-LEVEL OF LEAD EXPOSURE ON BLOOD PRESSURE AND FUNCTION OF THE RAT ISOLATED HEART

Pages

  289-297

Abstract

 Exposure to low levels of LEAD ACETATE can induce HYPERTENSION in both human and experimental animals. The exact mechanisms of lead-induced HYPERTENSION are not well-known, but its pathogenesis could be explained by changes in the heart rate and contractility. In present study, the effects of 100 ppm lead exposure in drinking water (in the periods of 4, 8 and 12 weeks) on blood pressure and some physiologic parameters (electrocardiography, heart rate, contractility and coronary flow) of isolated rat heart was investigated, using Langendorff ISOLATED HEART set up. The ISOLATED HEARTs were perfused with Krebs-Henseleit solution at 37oC and pH=7.4, gassed with 95% O2 + 5% CO2. All data were digitized by a software program for further analysis. The blood pressure in 8- and 12-week lead-treated groups was significantly increased compared with those of the control group. The ECG findings showed the incidence of arrhythmia and conduction abnormality only in the late phases of exposure (12 weeks). The heart rate (HR) and contractility were significantly higher in 8- and 12-week lead-treated rats but not in 4-week group. Finally, no significant changes were observed in coronary flow.These results indicate that: 1) Low levels of lead exposure in the early phase would not significantly affect ECG. 2) Low levels of lead exposure would impose changes to ECG in the late phases of exposure. 3) This levels of lead exposure can increase HR and CARDIAC CONTRACTILITY with no effect on coronary flow. Thereby, it can be concluded that observed changes in lead-treated rats might participate in induction of HYPERTENSION.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BADALZADEH, R., NOUROUZZADEH, ALI, HEYDARI, AZHDAR, ASGARI, A.R., & KHOUSHBATEN, A.. (2008). EFFECTS OF LOW-LEVEL OF LEAD EXPOSURE ON BLOOD PRESSURE AND FUNCTION OF THE RAT ISOLATED HEART. KOWSAR MEDICAL JOURNAL, 12(4), 289-297. SID. https://sid.ir/paper/33023/en

    Vancouver: Copy

    BADALZADEH R., NOUROUZZADEH ALI, HEYDARI AZHDAR, ASGARI A.R., KHOUSHBATEN A.. EFFECTS OF LOW-LEVEL OF LEAD EXPOSURE ON BLOOD PRESSURE AND FUNCTION OF THE RAT ISOLATED HEART. KOWSAR MEDICAL JOURNAL[Internet]. 2008;12(4):289-297. Available from: https://sid.ir/paper/33023/en

    IEEE: Copy

    R. BADALZADEH, ALI NOUROUZZADEH, AZHDAR HEYDARI, A.R. ASGARI, and A. KHOUSHBATEN, “EFFECTS OF LOW-LEVEL OF LEAD EXPOSURE ON BLOOD PRESSURE AND FUNCTION OF THE RAT ISOLATED HEART,” KOWSAR MEDICAL JOURNAL, vol. 12, no. 4, pp. 289–297, 2008, [Online]. Available: https://sid.ir/paper/33023/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button