مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

658
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

112
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A COMPARISON OF HEAT GENERATION IN DIFFERENT DEPTHS OF IMPLANT DRILLING SITE WITH AND WITHOUT A SLEEVE

Author(s)

VAFAEE FARIBORZ | FIROUZ FARNAZ | KHOSHHAL KHOJASTEH ZANJANI MASOUMEH | MOSHIRI ZAHRA | RANJZAD HADI | Issue Writer Certificate 

Pages

  24-29

Abstract

 Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve.Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths (3,6, and 9 mms). Data was analyzed with a three-way analysis of variance by Newman–Keulsmultiple comparison procedure. The significance level was set to a p-value of 0.05.Results: The mean maximum TEMPERATURE with a sleeve was 35.4°C and without a sleeve was 34.5°C. Thermal rise was lowest in the sleeve group and highest in the sleeveless group. There was a significant difference between the sleeve and nonsleeve group (P= 0.002). There was also no significant differences between the different depths of the three measurements (P= 0.068).Conclusion: Within the scope of this invitro study, thermal rise during implant site preparation was lower in conventional drilling compared to the use of a sleeve. Hence, the difference was statistically significant.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    VAFAEE, FARIBORZ, FIROUZ, FARNAZ, KHOSHHAL KHOJASTEH ZANJANI, MASOUMEH, MOSHIRI, ZAHRA, & RANJZAD, HADI. (2016). A COMPARISON OF HEAT GENERATION IN DIFFERENT DEPTHS OF IMPLANT DRILLING SITE WITH AND WITHOUT A SLEEVE. JOURNAL OF DENTOMAXILLOFACIAL RADIOLOGY, PATHOLOGY AND SURGERY, 5(1), 24-29. SID. https://sid.ir/paper/331567/en

    Vancouver: Copy

    VAFAEE FARIBORZ, FIROUZ FARNAZ, KHOSHHAL KHOJASTEH ZANJANI MASOUMEH, MOSHIRI ZAHRA, RANJZAD HADI. A COMPARISON OF HEAT GENERATION IN DIFFERENT DEPTHS OF IMPLANT DRILLING SITE WITH AND WITHOUT A SLEEVE. JOURNAL OF DENTOMAXILLOFACIAL RADIOLOGY, PATHOLOGY AND SURGERY[Internet]. 2016;5(1):24-29. Available from: https://sid.ir/paper/331567/en

    IEEE: Copy

    FARIBORZ VAFAEE, FARNAZ FIROUZ, MASOUMEH KHOSHHAL KHOJASTEH ZANJANI, ZAHRA MOSHIRI, and HADI RANJZAD, “A COMPARISON OF HEAT GENERATION IN DIFFERENT DEPTHS OF IMPLANT DRILLING SITE WITH AND WITHOUT A SLEEVE,” JOURNAL OF DENTOMAXILLOFACIAL RADIOLOGY, PATHOLOGY AND SURGERY, vol. 5, no. 1, pp. 24–29, 2016, [Online]. Available: https://sid.ir/paper/331567/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button