مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

363
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

125
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPLICATIONS OF MINIMALLY INVASIVE PERCUTANEOUS PLATING FOR DISTAL TIBIAL FRACTURES

Pages

  0-0

Abstract

 Background: The management of DISTAL TIBIA FRACTURES continues to remain a source of controversy and debate.Objectives: The aim of this study was to evaluate the various COMPLICATIONS of MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS (MIPPO) using a locking plate for closed FRACTURES of DISTAL TIBIA in a retrospective study.Patients and Methods: Twenty-five patients with DISTAL TIBIAl FRACTURES, treated by MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS, were evaluated in a retrospective study. We studied the rate, probable etiological factors and preventive and corrective measures of various COMPLICATIONS associated with minimally invasive plating of DISTAL TIBIA.Results: Mean age of the patients was 41.16 years (range 22 - 65). There were 13 male and 12 female patients. All FRACTURES united at an average duration of 16.8 weeks. There were two cases of superficial and two cases of deep infection, and deep infections required removal of hardware for cure. There were four cases of ankle stiffness, most of them occurring in intra-articular FRACTURES, three cases of palpable implant, three cases of malunion, one case of loss of reduction and one patient required reoperation. The average AO foot and ankle score was 83.6.Conclusions: We found MIPPO using locking plate to be a safe and effective method for the treatment of DISTAL TIBIAl FRACTURES in properly selected patients yet can result in a variety of COMPLICATIONS if proper precautions before, during and after surgery are not taken care of.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    MUZAFFAR, NASIR, BHAT, RAFIQ, & YASIN, MOHAMMAD. (2016). COMPLICATIONS OF MINIMALLY INVASIVE PERCUTANEOUS PLATING FOR DISTAL TIBIAL FRACTURES. TRAUMA MONTHLY, 21(3), 0-0. SID. https://sid.ir/paper/334154/en

    Vancouver: Copy

    MUZAFFAR NASIR, BHAT RAFIQ, YASIN MOHAMMAD. COMPLICATIONS OF MINIMALLY INVASIVE PERCUTANEOUS PLATING FOR DISTAL TIBIAL FRACTURES. TRAUMA MONTHLY[Internet]. 2016;21(3):0-0. Available from: https://sid.ir/paper/334154/en

    IEEE: Copy

    NASIR MUZAFFAR, RAFIQ BHAT, and MOHAMMAD YASIN, “COMPLICATIONS OF MINIMALLY INVASIVE PERCUTANEOUS PLATING FOR DISTAL TIBIAL FRACTURES,” TRAUMA MONTHLY, vol. 21, no. 3, pp. 0–0, 2016, [Online]. Available: https://sid.ir/paper/334154/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button