Title

VALIDATION OF OPTIMUM ROI SIZE FOR 123I-FP-CIT SPECT IMAGING USING A 3D MATHEMATICAL CYLINDER PHANTOM

Pages

  139-148

Abstract

 Objective(s): The PARTIAL VOLUME EFFECT (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of SPECIFIC BINDING RATIO (SBR). A large ROI (region of interest) set using the SOUTHAMPTON METHOD is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and validate the SOUTHAMPTON METHOD using a three-dimensional mathematical cylinder (3D-MAC) phantom.Methods: We used ROIs sizes of 27, 36, 44, 51, 61, 68, and 76 mm for targets with diameters 40, 20, and 10 mm on reference and processed images reconstructed using the 3D-MAC phantom. Contrast values and SBR were compared with the theoretical values to obtain the optimal ROI size.Results: The contrast values in the ROI with diameters of 51 (target: 40 mm in diameter) and 44 (target: 20 mm in diameter) mm matched the theoretical values. However, this value did not correspond with the 10-mm-diameter target. The SBR matched the theoretical value with an ROI of >44 mm in the 20-mm-diameter target; but, it was under- and overestimated under any other conditions.Conclusion: These results suggested that an ROI should be 4-2 folds larger than the target size without PVE, and that the SOUTHAMPTON METHOD was remarkably accurate.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ONISHI, HIDEO, SAKAI, TAKAYUKI, SHIROMOTO, OSAMU, & AMIJIMA, HIZURU. (2018). VALIDATION OF OPTIMUM ROI SIZE FOR 123I-FP-CIT SPECT IMAGING USING A 3D MATHEMATICAL CYLINDER PHANTOM. ASIA OCEANIA JOURNAL OF NUCLEAR MEDICINE AND BIOLOGY, 6(2), 139-148. SID. https://sid.ir/paper/342106/en

    Vancouver: Copy

    ONISHI HIDEO, SAKAI TAKAYUKI, SHIROMOTO OSAMU, AMIJIMA HIZURU. VALIDATION OF OPTIMUM ROI SIZE FOR 123I-FP-CIT SPECT IMAGING USING A 3D MATHEMATICAL CYLINDER PHANTOM. ASIA OCEANIA JOURNAL OF NUCLEAR MEDICINE AND BIOLOGY[Internet]. 2018;6(2):139-148. Available from: https://sid.ir/paper/342106/en

    IEEE: Copy

    HIDEO ONISHI, TAKAYUKI SAKAI, OSAMU SHIROMOTO, and HIZURU AMIJIMA, “VALIDATION OF OPTIMUM ROI SIZE FOR 123I-FP-CIT SPECT IMAGING USING A 3D MATHEMATICAL CYLINDER PHANTOM,” ASIA OCEANIA JOURNAL OF NUCLEAR MEDICINE AND BIOLOGY, vol. 6, no. 2, pp. 139–148, 2018, [Online]. Available: https://sid.ir/paper/342106/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button