مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

306
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

201
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CONDUCTION DISORDERS IN CONTINUOUS VERSUS INTERRUPTED SUTURING TECHNIQUE IN VENTRICULAR SEPTAL DEFECT SURGICAL REPAIR

Pages

  0-0

Abstract

 Background: Ventricular septal DEFECTs (VSD) is one of the most frequent congenital cardiac malformations and cardiac conduction disorders are still one of the serious postoperative complications in this surgery.Objectives: This study aimed to compare the incidence of conduction disorders with the use of continuous compared to interrupted suturing techniques in VSD surgical repair.Patients and Methods: Previously recorded data of 231 patients who underwent surgical closure of VSD between January 2009 and January 2012 at the Rajaie cardiovascular medical and research center were retrospectively reviewed. VSD surgical repair was performed using continues suturing technique in group A patients (n=163, 70.6%) and interrupted suturing technique in group B patients (n=68, 29.4%).Results: The most common concomitant congenital anomaly was Tetralogy of Fallot (27.3%). Twenty-four (10.4%) patients had intraoperative CARDIAC ARRHYTHMIA, including 19 (8.2%) transient and 5 (2.2 %) permanent arrhythmia. During their ICU stay, ventricular arrhythmia and complete heart block were observed in 34 (14.7%) and 5 patients (2.2%), respectively. At the time of the last follow-up, incomplete right bundle branch block (RBBB), complete RBBB, RBBB with left anterior hemi-block, and complete heart block were identified in 84 (36.4%), 42 (18.2%), 29 (12.6%), and 5 patients (2.2%), respectively. The results revealed that group A patients were most likely to have had CARDIAC ARRHYTHMIAs during their ICU stay and at the time of last follow-up (P<0.001), while the intraoperative incidence of CARDIAC ARRHYTHMIA during surgery was not statistically significant between the two groups (P=0.06).Conclusions: In the absence of any statistical differences in the other risk factors between the two groups, the difference in the incidence of conduction disorders can be attributed to the type of suturing used during the procedure.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    GHOLAMPOUR DEHAKI, MAZIAR, ZAREH, ASGHAR, BABAKI, SOLMAZ, & JAVADIKASGARI, HODA. (2016). CONDUCTION DISORDERS IN CONTINUOUS VERSUS INTERRUPTED SUTURING TECHNIQUE IN VENTRICULAR SEPTAL DEFECT SURGICAL REPAIR. RESEARCH IN CARDIOVASCULAR MEDICINE, 5(1), 0-0. SID. https://sid.ir/paper/346926/en

    Vancouver: Copy

    GHOLAMPOUR DEHAKI MAZIAR, ZAREH ASGHAR, BABAKI SOLMAZ, JAVADIKASGARI HODA. CONDUCTION DISORDERS IN CONTINUOUS VERSUS INTERRUPTED SUTURING TECHNIQUE IN VENTRICULAR SEPTAL DEFECT SURGICAL REPAIR. RESEARCH IN CARDIOVASCULAR MEDICINE[Internet]. 2016;5(1):0-0. Available from: https://sid.ir/paper/346926/en

    IEEE: Copy

    MAZIAR GHOLAMPOUR DEHAKI, ASGHAR ZAREH, SOLMAZ BABAKI, and HODA JAVADIKASGARI, “CONDUCTION DISORDERS IN CONTINUOUS VERSUS INTERRUPTED SUTURING TECHNIQUE IN VENTRICULAR SEPTAL DEFECT SURGICAL REPAIR,” RESEARCH IN CARDIOVASCULAR MEDICINE, vol. 5, no. 1, pp. 0–0, 2016, [Online]. Available: https://sid.ir/paper/346926/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button