Title

Automatic Mode Switch (AMS) Causes Less Synchronization

Pages

  0-0

Abstract

 Introduction: Cardiac resynchronization devices are part of modern heart failure management. After implantation, we analyze and program devices in an attempt to ensure their success. Biventricular Pacing should be 98% or more for the lowest mortality and best symptom improvement. Case Presentation: In this case series, we present a combination of far field sensing and Automatic Mode Switching (AMS) in six patients. It is found that this combination causes ventricular sensing (VS) episodes with wide QRS and no synchronization. We turn off the AMS and alleviate the problem. Conclusions: Switching AMS off may increase Biventricular Pacing in some patients.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    JORAT, MOHAMMADVAHID, & Nikoo, Mohammadhossein. (2016). Automatic Mode Switch (AMS) Causes Less Synchronization. RESEARCH IN CARDIOVASCULAR MEDICINE, 5(2), 0-0. SID. https://sid.ir/paper/346974/en

    Vancouver: Copy

    JORAT MOHAMMADVAHID, Nikoo Mohammadhossein. Automatic Mode Switch (AMS) Causes Less Synchronization. RESEARCH IN CARDIOVASCULAR MEDICINE[Internet]. 2016;5(2):0-0. Available from: https://sid.ir/paper/346974/en

    IEEE: Copy

    MOHAMMADVAHID JORAT, and Mohammadhossein Nikoo, “Automatic Mode Switch (AMS) Causes Less Synchronization,” RESEARCH IN CARDIOVASCULAR MEDICINE, vol. 5, no. 2, pp. 0–0, 2016, [Online]. Available: https://sid.ir/paper/346974/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button