مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

605
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom

Pages

  177-187

Abstract

 Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiotherapy of heterogeneous chest phantom. EBT3 film and Delta4 were used for dose measurement in the phantom. The 95% global Gamma index accepted by the criteria of 3. 3% mm and the dose threshold 20% as the standard criteria were considered in this study. The Gamma index of the film and Delta4 were acquired by the verisoft and Delta4 software, respectively. Results: The mean Gamma index with standard criteria between treatment planning system (TPS) dose calculations and film measurements was 96. 95%, while it was equal to 97. 7% and 98. 45% between TPS calculations and 2D and 3D Delta4 cases, respectively. The mean 3D gamma analysis of the Delta4 with the given standard criteria was 0. 75% and 1. 5% higher than their 2D gamma analysis of the Delta4 and film, respectively. The mean Gamma index value of film and Delta4 according to the plan B at the standard criteria was 0. 24% higher than plan A (97. 7% vs 97. 46%). Conclusion: Both film and Delta4 showed acceptable standard Gamma index for two plans implemented on the chest phantom using IMRT technique. So, according to the results of this study, it is concluded that in the centers where Delta4 is not available, EBT3 films with a simple heterogeneous phantom can be an alternative method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Abedi Firouzjah, Razzagh, Nickfarjam, Abolfazl, & BAKHSHANDEH, MOHSEN. (2018). A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom. JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES, 26(2 ), 177-187. SID. https://sid.ir/paper/35778/en

    Vancouver: Copy

    Abedi Firouzjah Razzagh, Nickfarjam Abolfazl, BAKHSHANDEH MOHSEN. A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom. JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2018;26(2 ):177-187. Available from: https://sid.ir/paper/35778/en

    IEEE: Copy

    Razzagh Abedi Firouzjah, Abolfazl Nickfarjam, and MOHSEN BAKHSHANDEH, “A comparison between GafchromicTM EBT3 film and Delta4® phantom in IMRT technique of a heterogeneous chest phantom,” JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES, vol. 26, no. 2 , pp. 177–187, 2018, [Online]. Available: https://sid.ir/paper/35778/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button