مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

704
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

IN-VIVO DOSIMETRY IN EXTERNAL RADIOTHERAPY OF BRAIN TUMORS WITH 15 MV PHOTON USING EBT3 GAFCHROMIC FILM

Pages

  282-289

Abstract

 Background and purpose: IN-VIVO DOSIMETRY is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the ENTRANCE DOSEs without the BUILD-UP CAP for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS).Materials and methods: The study was performed on 30 patients with brain tumor undergoing radiotherapy by 15MV photons of a Siemens linac. A novel method was developed for IN-VIVO DOSIMETRY, without the need to use BUILD-UP CAPs and was used to estimate conversion coeficients in a solid water phantom for various irradiation conditions with and without a 30o wedge for 5x5, 10x10, and 15x15cm2 field sizes and 80, 90 and 100cm SSDs. The conversion coeficients provided ratios of surface doses measured by gafchromic films to those of an ioniztion chamber for various conditions.Results: For 4 patients, more than 5% error was noted in in-vivo doses. The mean and standard deviation of errors between the doses measured and those calculated with TPS for the patients’ skulls were -2.23% and 3.36%, respectively. The CONVERSION COEFFICIENTs increased by increase in field size and decrease of SSD. The CONVERSION COEFFICIENTs for all irradiation conditions were greater for the fields with the wedge than those without it.Conclusion: The novel dosimetry method developed for measuring the ENTRANCE DOSE without any need to use BUILD-UP CAPs usual in conventional dosimetry methods, not only makes no disruption in the dose reached to patient’s treatment volume, but also provides an accurate estimation of ENTRANCE DOSE in clinical situations.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    REZAEIJO, SEYEDMASOUD, HASHEMI, BIJAN, & MAHDAVI, SEIED RABI. (2017). IN-VIVO DOSIMETRY IN EXTERNAL RADIOTHERAPY OF BRAIN TUMORS WITH 15 MV PHOTON USING EBT3 GAFCHROMIC FILM. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 26(144), 282-289. SID. https://sid.ir/paper/45408/en

    Vancouver: Copy

    REZAEIJO SEYEDMASOUD, HASHEMI BIJAN, MAHDAVI SEIED RABI. IN-VIVO DOSIMETRY IN EXTERNAL RADIOTHERAPY OF BRAIN TUMORS WITH 15 MV PHOTON USING EBT3 GAFCHROMIC FILM. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2017;26(144):282-289. Available from: https://sid.ir/paper/45408/en

    IEEE: Copy

    SEYEDMASOUD REZAEIJO, BIJAN HASHEMI, and SEIED RABI MAHDAVI, “IN-VIVO DOSIMETRY IN EXTERNAL RADIOTHERAPY OF BRAIN TUMORS WITH 15 MV PHOTON USING EBT3 GAFCHROMIC FILM,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 26, no. 144, pp. 282–289, 2017, [Online]. Available: https://sid.ir/paper/45408/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top