مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

422
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran

Pages

  2091-2098

Abstract

 Introduction: Today Electrophysiology studies and Ablation have been developed due to increasing arrhythmias disorder of heart. In these diagnostic – treatments methods, the use of Fluoroscopy can be causes patient radiation dose, therefore evaluation of patient's Absorbed dose is necessary to protection of the radiation. The aim of this study was to evaluate the Absorbed dose in patients undergoing electrophysiology and cardiac Ablation and to estimate their risk of cancer in Yazd Afshar Hospital. Methods: This study was a cross-sectional study. In this study, the mean Absorbed dose of referral patients for Electrophysiology studies and Ablation had been measured in the cat. Lab of Afshar Hospital, Yazd. The dosimeter had been used in this research was KAP meter, the M4 DIAMENTOR made in Germany that was able to measure Dose-Area product and time of the Fluoroscopy. The patient effective dose was calculated by the PCXMC software from Dose-Area product. Results: The mean dose-area in Ablation and Electrophysiology studies was respectively 153. 34± 105. 32 and 5. 62 14. 88 Gy. cm2 and the radiation time range was recorded 3. 32 to 68. 65 minutes and 1. 03 to 6. 28 minutes, respectively. The mean effective dose of Ablation and Electrophysiology studies were respectively 16. 38 and 1. 65 mSv. The cancer risk per ten thousands of patients, who were under the Ablation and electrophysiology examinations were estimated 13 and 1. 3 people, respectively. Conclusion: Increasing of patient dose due to Ablation in this study relation to the other studies can be due to long old of image intensifier device.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Bouzarjomehri, Fatollah, Omidvar, Fereshteh, Zare, Mohammad Hossein, & Nakhaeine Nejad, Mashallah. (2020). Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran. JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES, 27(11 ), 2091-2098. SID. https://sid.ir/paper/36376/en

    Vancouver: Copy

    Bouzarjomehri Fatollah, Omidvar Fereshteh, Zare Mohammad Hossein, Nakhaeine Nejad Mashallah. Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran. JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2020;27(11 ):2091-2098. Available from: https://sid.ir/paper/36376/en

    IEEE: Copy

    Fatollah Bouzarjomehri, Fereshteh Omidvar, Mohammad Hossein Zare, and Mashallah Nakhaeine Nejad, “Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran,” JOURNAL OF SHAHID SADOUGHI UNIVERSITY OF MEDICAL SCIENCES, vol. 27, no. 11 , pp. 2091–2098, 2020, [Online]. Available: https://sid.ir/paper/36376/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top