مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

6,409
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE ACCURACY OF ULTRASOUND FOR ESTIMATING OF BIRTH WEIGHT

Pages

  133-138

Abstract

 Background and purpose: Accurate ESTIMATION of fetal weight is of paramount importance in the management of labor and delivery and may be related to critical points of decision making and proper management. This study was done in order to compare the accuracy of clinical and ultrasonic ESTIMATION of fetal weight in Imam Khomeini hospital of Sari, Iran. Materials and methods: During this study (March 2000- December 2004) 174 pregnant women met the inclusion criteria. Written consent was obtained from the patients and fetal weight was estimated by clinical examination and Johnson's formula at their admission by one physicians. Then they were transferred to the ULTRASOUND ward and EFW was estimated by one sonologist. Finally, all newborns, weight were measured by one scale. Statistical analysis was done by frequency, Diagram, paired sample T Test. Results: The mean of the age of subjects was 24.95± 4.59 years and their mean weight was 72.07+1104 kg and the mean of their gestational age was 38 weeks± 5days. paired T test showed that there is no significant differences between estimated fetal weight by ULTRASOUND and actual BIRTH WEIGHT In SGA and LGA group EFW by this method had a significant difference with actual BIRTH WEIGHT (P<0.001). In AGA group BIRTH WEIGHT had no any significant difference with actual BIRTH WEIGHT. Conclusion: Accuracy of weight ESTIMATION using the clinical examination and ULTRASOUND was found to be low in SGA and LGA groups. In LGA groups Johnson’s formula was more accurate than others. However, a systematic review with methaanalysis was recommended.  

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KHANI, S., MAJIDI, H., MOHAMMADPOUR TAHAMTAN, R.A., ABDI, R.A., ZARE, K., & FOULADI, E.. (2006). THE ACCURACY OF ULTRASOUND FOR ESTIMATING OF BIRTH WEIGHT . JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 16(50), 133-138. SID. https://sid.ir/paper/44500/en

    Vancouver: Copy

    KHANI S., MAJIDI H., MOHAMMADPOUR TAHAMTAN R.A., ABDI R.A., ZARE K., FOULADI E.. THE ACCURACY OF ULTRASOUND FOR ESTIMATING OF BIRTH WEIGHT . JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2006;16(50):133-138. Available from: https://sid.ir/paper/44500/en

    IEEE: Copy

    S. KHANI, H. MAJIDI, R.A. MOHAMMADPOUR TAHAMTAN, R.A. ABDI, K. ZARE, and E. FOULADI, “THE ACCURACY OF ULTRASOUND FOR ESTIMATING OF BIRTH WEIGHT ,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 16, no. 50, pp. 133–138, 2006, [Online]. Available: https://sid.ir/paper/44500/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button