مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

774
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

BRIEF REPORT: A MONTE CARLO INVESTIGATION ON THE EFFECT OF FIELD SIZE ON NEUTRON SPECTRUM IN ELEKTA SL 75/25 LINAC ON 18 MV

Pages

  257-262

Abstract

 Background and purpose: High-energy photon beams above 8-10 MV used in external radiation therapy produce neutron in dealing with the LINEAR ACCELERATOR components and other parts in radiation field. The weakening of neutrons due to the closing jaws collimator angle, in smaller FIELD SIZEs can also be a contributing factor in changing the neutron spectrum. Since a direct measurement of the neutron flux and spectrum require complex measurements in treatment room, the MONTE CARLO is an alternative method for determining the true environmental neutron spectrum.Materials and methods: Geometry of LINEAR ACCELERATOR Elekta SL75/25 was designed in FLUKA simulation code and its validation was tested. Spectrum of neutrons produced in the accelerator was determined in the center of four FIELD SIZEs of 20 × 20, 15 × 15, 10 × 10, and 5 × 5 cm2. Data analysis was done applying Mann-Whitney test.Results: In the condition with flattening filter, significant differences was found in the neutron spectrum only in 5 × 5 to 15 × 15 cm2 and 5 × 5 to 20 × 20 cm2 FIELD SIZEs (P<0.05).Conclusion: Our results of the neutron spectrum using FLUKA simulation code are in a good conformity with the results of practical dosimetry of other researchers; therefore, checking the neutron flux in radiotherapy by simulation can be an appropriate solution to improve patient treatment and protection issues. Since neutron dose increases with an increase in FIELD SIZE, so, we can conclude that FIELD SIZE influences secondary effects of treatment.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SISTANI, SOROUSH, SAFARI, MOHAMMAD JAVAD, & HEJAZI, PAYMAN. (2016). BRIEF REPORT: A MONTE CARLO INVESTIGATION ON THE EFFECT OF FIELD SIZE ON NEUTRON SPECTRUM IN ELEKTA SL 75/25 LINAC ON 18 MV. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 26(143), 257-262. SID. https://sid.ir/paper/45250/en

    Vancouver: Copy

    SISTANI SOROUSH, SAFARI MOHAMMAD JAVAD, HEJAZI PAYMAN. BRIEF REPORT: A MONTE CARLO INVESTIGATION ON THE EFFECT OF FIELD SIZE ON NEUTRON SPECTRUM IN ELEKTA SL 75/25 LINAC ON 18 MV. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2016;26(143):257-262. Available from: https://sid.ir/paper/45250/en

    IEEE: Copy

    SOROUSH SISTANI, MOHAMMAD JAVAD SAFARI, and PAYMAN HEJAZI, “BRIEF REPORT: A MONTE CARLO INVESTIGATION ON THE EFFECT OF FIELD SIZE ON NEUTRON SPECTRUM IN ELEKTA SL 75/25 LINAC ON 18 MV,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 26, no. 143, pp. 257–262, 2016, [Online]. Available: https://sid.ir/paper/45250/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button