مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

600
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATING THE EFFECT OF AIR INHOMOGENEITY ON DOSE CALCULATIONS OF TRACHEA HDR BRACHYTHERAPY USING EDR2 FILM

Pages

  346-351

Abstract

 Background and purpose: Dose calculations in TRACHEA HDR BRACHYTHERAPY treatment planning systems are greatly based on TG-43 protocol in which, all materials including air inside trachea are treated the same as water. The aim of this study was to survey the effect of air on dose calculations of Flexiplan treatment planning system in TRACHEA HDR BRACHYTHERAPY.Materials and methods: To evaluate the effect of AIR INHOMOGENEITY, a neck-equivalent plexiglass cylindrical phantom was used. Dose measurement was carried out by EDR2 FILM. Treatment planning and irradiation were performed using Flexiplan software and Flexitron brachytherapy system, respectively.Results: The results showed that considering the air inside trachea as water increases the absorbed dose by 12% which can lead to increment of patient dose.Conclusion: A significant difference was seen between dosimetry results in the two conditions. Therefore, taking the air similar to water has a considerable effect on dose calculations of TRACHEA HDR BRACHYTHERAPY and accuracy of treatment plan performed.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HOSSEINI DAGHIGH, SEYED MOHSEN, BAGHANI, HAMIDREZA, AGHAMIRI, SEYED MAHMOUD REZA, & MAHDAVI, SEIED RABI. (2017). EVALUATING THE EFFECT OF AIR INHOMOGENEITY ON DOSE CALCULATIONS OF TRACHEA HDR BRACHYTHERAPY USING EDR2 FILM. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 26(144), 346-351. SID. https://sid.ir/paper/45407/en

    Vancouver: Copy

    HOSSEINI DAGHIGH SEYED MOHSEN, BAGHANI HAMIDREZA, AGHAMIRI SEYED MAHMOUD REZA, MAHDAVI SEIED RABI. EVALUATING THE EFFECT OF AIR INHOMOGENEITY ON DOSE CALCULATIONS OF TRACHEA HDR BRACHYTHERAPY USING EDR2 FILM. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2017;26(144):346-351. Available from: https://sid.ir/paper/45407/en

    IEEE: Copy

    SEYED MOHSEN HOSSEINI DAGHIGH, HAMIDREZA BAGHANI, SEYED MAHMOUD REZA AGHAMIRI, and SEIED RABI MAHDAVI, “EVALUATING THE EFFECT OF AIR INHOMOGENEITY ON DOSE CALCULATIONS OF TRACHEA HDR BRACHYTHERAPY USING EDR2 FILM,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 26, no. 144, pp. 346–351, 2017, [Online]. Available: https://sid.ir/paper/45407/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button